MPR121QR2 Freescale Semiconductor, MPR121QR2 Datasheet - Page 26

IC CTLR TOUCH SENSOR 20-QFN

MPR121QR2

Manufacturer Part Number
MPR121QR2
Description
IC CTLR TOUCH SENSOR 20-QFN
Manufacturer
Freescale Semiconductor
Type
Capacitive, Proximity Sensorr
Datasheet

Specifications of MPR121QR2

Number Of Inputs/keys
12 Key
Data Interface
I²C, Serial
Voltage - Supply
1.71 V ~ 3.6 V
Current - Supply
29µA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-UQFN, 20-µQFN
Output Type
Logic
Interface
I²C
Input Type
Logic
Supply Voltage
2.5 V to 3.6 V
Dimensions
3 mm L x 3 mm W x 0.65 mm H
Temperature Range
- 40 C to + 85 C
Termination Style
SMD/SMT
Supply Current
29µA
Ic Interface Type
I2C
Supply Voltage Range
1.71V To 3.6V
Sensor Case Style
QFN
No. Of Pins
20
Operating Temperature Range
-40°C To +85°C
Interface Type
I2C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MPR121QR2
MPR121QR2TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPR121QR2
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MPR121QR2
0
MPR121
26
AN3891: MPR121 Baseline System
INTRODUCTION
tightly coupled. The purpose of the baseline filter is to “filter out touches” resulting in a system that is similar to a long term
average but also takes into account that one specific signature. A touch must have different properties than noise and
environmental change with respect to the filter response. This is accomplished through four register types that operate under
different conditions. These are Max Half Delta (MHD), Noise Half Delta (NHD), Noise Count Limit (NCL) and Filter Delay Limit
(FDL).
MAX HALF DELTA (NHD)
Touch acquisition takes a few different parts of the system in order to detect touch. The baseline filter and touch detection are
Table 22. Max Half Delta Register Field Descriptions
Reset:
Field
MHD
AFE AQUISITION
5:0
W
R
1 - 32 μs
DATA
RAW
7
0
0
= Unimplemented
Max Half Delta – The Max Half Delta determines the largest magnitude of
variation to pass through the third level filter.
000000 DO NOT USE THIS CODE
000001 Encoding 1 – Sets the Max Half Delta to 1
~
111111 Encoding 63 – Sets the Max Half Delta to 63
6
0
0
Figure 24. Data Flow in the MPR121
1 - 128 μs
FILTER
1st
5
0
4
0
FILTER
2nd
Description
4 - 2048 μs
3
0
STATUS REGISTER
MHD
TOUCH
IRQ
2
0
BASELINE
FILTER
1
0
Freescale Semiconductor
0
0
Sensors

Related parts for MPR121QR2