MPR121QR2 Freescale Semiconductor, MPR121QR2 Datasheet - Page 21

IC CTLR TOUCH SENSOR 20-QFN

MPR121QR2

Manufacturer Part Number
MPR121QR2
Description
IC CTLR TOUCH SENSOR 20-QFN
Manufacturer
Freescale Semiconductor
Type
Capacitive, Proximity Sensorr
Datasheet

Specifications of MPR121QR2

Number Of Inputs/keys
12 Key
Data Interface
I²C, Serial
Voltage - Supply
1.71 V ~ 3.6 V
Current - Supply
29µA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-UQFN, 20-µQFN
Output Type
Logic
Interface
I²C
Input Type
Logic
Supply Voltage
2.5 V to 3.6 V
Dimensions
3 mm L x 3 mm W x 0.65 mm H
Temperature Range
- 40 C to + 85 C
Termination Style
SMD/SMT
Supply Current
29µA
Ic Interface Type
I2C
Supply Voltage Range
1.71V To 3.6V
Sensor Case Style
QFN
No. Of Pins
20
Operating Temperature Range
-40°C To +85°C
Interface Type
I2C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MPR121QR2
MPR121QR2TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPR121QR2
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MPR121QR2
0
Sensors
Freescale Semiconductor
ELE8-11, ELEPROX OUT OF RANGE STATUS REGISTER
Table 19. ELE8-11, ELEPROX Out Of Range Status Register Field Descriptions
ELEPROXS
Reset:
ARFF
ACFF
E11S
E10S
Field
E9S
E8S
7
6
4
3
2
1
0
W
R
ARFF
7
0
Automatic Reconfiguration Fail Flag – The Automatic Reconfiguration Fail Flag shows is the
OOR was triggered during a reconfiguration cycle.
0 – Auto-reconfiguration did not cause the OOR flag
1 – Auto-reconfiguration did cause the OOR flag
Automatic Configuration Fail Flag – The Automatic Configuration Fail Flag shows is the OOR
was triggered during an initial configuration cycle.
0 – Auto-configuration did not cause the OOR flag
1 – Auto-configuration did cause the OOR flag
Electrode PROX OOR Status – The Electrode PROX OOR Status shows if the AUTO-CONFIG
has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 11 OOR Status – The Electrode 11 OOR Status shows if the AUTO-CONFIG has
failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 10 OOR Status – The Electrode 10 OOR Status shows if the AUTO-CONFIG has
failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 9 OOR Status – The Electrode 9 OOR Status shows if the AUTO-CONFIG has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Electrode 8 OOR Status – The Electrode 8 OOR Status shows if the AUTO-CONFIG has failed.
0 – Auto-configuration Successful
1 – Auto-configuration Failed
Figure 17. ELE8-11, ELEPROX Out Of Range Status Register
= Unimplemented
ACFF
6
0
5
0
0
ELEPROXS
4
0
Description
E11S
3
0
E10S
2
0
E9S
1
0
E8S
0
0
MPR121