SI3019-F-FM Silicon Laboratories Inc, SI3019-F-FM Datasheet - Page 38

no-image

SI3019-F-FM

Manufacturer Part Number
SI3019-F-FM
Description
IC VOICE DAA GCI/PCM/SPI 20-QFN
Manufacturer
Silicon Laboratories Inc
Series
-r
Datasheet

Specifications of SI3019-F-FM

Function
Data Access Arrangement (DAA)
Interface
GCI, PCM, SPI
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
8.5mA
Power (watts)
*
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
20-VFQFN Exposed Pad
Includes
*
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Si3050 + Si3011/18/19
5.27. Gain Control
The Si3050 supports multiple levels of gain and
attenuation for the transmit and receive paths.
The TXG2 and RXG2 bits (Registers 38–39) enable
gain or attenuation in 1 dB increments for the transmit
and receive paths (up to 12 dB gain and 15 dB
attenuation). The TGA2 and RGA2 bits select either
gain or attenuation. The TXG3 and RXG3 bits
5.28. Transhybrid Balance
The Si3050 contains an on-chip analog hybrid that
performs the 2- to 4-wire conversion and near-end echo
cancellation. This hybrid circuit is adjusted for each ac
termination setting selected to achieve a minimum
transhybrid balance of 20 dB when the line impedance
matches the impedance set by ACIM.
The Si3050 also offers a digital hybrid stage for
additional near-end echo cancellation. For each ac
termination setting, the eight programmable hybrid
registers (Registers 45–52) can be programmed with
coefficients to increase cancellation of real-world line
impedances. This digital filter can produce 10 dB or
greater of near-end echo cancellation in addition to the
trans-hybrid loss from the analog hybrid circuitry.
38
Si3050
DTX
DRX
To
Attenuation
Steps
1 dB
RXA2
TXG2
Steps
1 dB
Gain
Link
Digital
Filter
IIRE
TXG3
TXA3
Gain/ATT
0.1 dB
Steps
Figure 27. Si3011/18/19 Signal Flow Diagram
Gain/ATT
0.1 dB
Steps
Figure 28. Si3050 Signal Flow Diagram
RXG3
RXA3
Digital
Filter
IIRE
Steps
Gain
1 dB
RXG2
DAC
ADC
Rev. 1.4
Selectable
Attenuation
TXA2
200 Hz
Steps
HPF
1 dB
(Registers 40–41) enable gain or attenuation in 0.1 dB
increments up to 1.5 dB for the transmit and receive
paths. The TGA3 and RGA3 bits select either gain or
attenuation. The transmit and receive paths can be
individually muted with the TXM and RXM bits
(Register 15). The signal flow through the Si3050 and
the Si3011/18/19 is shown in Figures 27–28.
Coefficients are 2s complement, where unity is
represented as binary 0100 0000b, the maximum value
as binary 0111 1111b, and the minimum value as binary
1000 000b. See AN84 for a more detailed description of
the digital hybrid and how to use it.
Analog
Hybrid
Hybrid
Digital
ACT
0.6 Hz
HPF
Link
TX
Si3011/18/19
To
CO