Z16M1720ASG1868 Zilog, Z16M1720ASG1868 Datasheet - Page 293

no-image

Z16M1720ASG1868

Manufacturer Part Number
Z16M1720ASG1868
Description
IC PCMCIA INTERFACE 100-VQFP
Manufacturer
Zilog
Datasheet

Specifications of Z16M1720ASG1868

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
100-LQFP
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z16M1720ASG1868
Manufacturer:
Zilog
Quantity:
10 000
UM008101-0601
characteristics of the channels. With the exception of WR0, programming
the write registers requires two bytes. The first byte contains three bits (D2-
D0) that point to the selected register; the second byte is the actual control
word that is written into the register to configure the Z80 SIO.
After pointing to the selected register, a programmer can either read to test
the read register or write to initialize the write register. The Z80 SIO
software can be initialized in either a modular or structured mode, allowing
the programmer to use powerful block I/O instructions.
WR0 functions as a unique register because all the basic commands
(CM02-CMDO) can be accessed with a single byte. Reset (internal or
external) initializes the pointer bits D0-D2 to point to WR0.
The basic commands (CMD2-CMD0) and the CRC controls (CRC0,
CRC1) are contained in the first byte of any write register access. This
allows maximum flexibility and system control. Each channel contains
the following control registers. These registers are addressed as
commands, not data.
Write Register 0
WR0,
CRC reset codes and points to the other registers.
Table 12. Write Register 0
D7
CRC
Reset
Code
1
(Figure
D6
CRC
Reset
Code
0
114) is the command register; however, it is also used for
D5
CMD
2
D4
CMD
1
CMD
D3
0
D2
PTR
2
Z80 CPU Peripherals
Serial Input/Output
D1
PTR
1
User Manual
DO
PTR
0
273