JSH-42L3AD3-20 JDS UNIPHASE, JSH-42L3AD3-20 Datasheet - Page 36

no-image

JSH-42L3AD3-20

Manufacturer Part Number
JSH-42L3AD3-20
Description
Manufacturer
JDS UNIPHASE
Datasheet

Specifications of JSH-42L3AD3-20

Number Of Receivers
1
Operating Supply Voltage (typ)
3.3V
Operating Temperature Classification
Commercial
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Operating Temperature (max)
85C
Lead Free Status / Rohs Status
Compliant
JSH-42L3AD3-20S / 64P0682
LW 4x/2x/1x FC SFP with DDM
Monitor Data Table 4
JDSU Product Specification 21121822-001
Page 36 of 45
Address
114-115
118-119
120-127
1. The Digital Diagnostic Monitoring values and Alarm/Warning indicators will be set to zero, and Data Ready Bar will be set high, for
2. The data ready bar bit is held high during module power up and prior to the first transceiver sampling of the monitored values. The
3. Bytes 112-119 contain a set of non-latched alarm and warning flags. Users can choose to read these values and use them to ana-
4. The Vendor Specific area is further defined below in Vendor Specific Digital Diagnostic Monitor TX_FAULT Alarm/Warning Interrupt
Byte
112
112
112
113
113
113
116
116
116
116
116
116
116
116
117
117
117
certain failure mechanisms within the transceiver that do not affect the link capability of the transceiver. Refer to Vendor Specific
Digital Diagnostic Monitor TX_FAULT Alarm/Warning Interrupt on page 37 for additional information on transceiver Digital Diag-
nostic Monitoring status.
bit will be set low after each first successful sampling occurs and remain low until the transceiver looses power or a failure occurs.
The bit must be set low within 1 second of reaching a valid stable power supply level.
lyze the status of the transceiver as an alternative to decoding the real-time values in bytes 96-105. Alarm flags indicate levels that
are likely to be associated with link failures. Warning flags indicate levels that are outside of normal levels, but not necessarily
cause for immediate concern (could be used for end-of-life indicators).
on page 37.
5-0
5-0
Bit
All
All
All
2
1
0
7
6
7
6
5
4
3
2
1
0
7
6
TX Bias Low Alarm
TX Power High Alarm
TX Power Low Alarm
RX Power High Alarm
RX Power Low Alarm
Reserved
Reserved
Temp High Warning
Temp Low Warning
Voltage High Warning
Voltage Low Warning
TX Bias High Warning
TX Bias Low Warning
TX Power High Warning
TX Power Low Warning
RX Power High Warning
RX Power Low Warning
Reserved
Reserved
Vendor Specific
Diagnostic Data Values, Alarms, Warnings and Status Bits
Name
4
1,3
1, 3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1, 3
1,3
1,3
1,3
Set when Laser Diode Current is below the bytes 18-19 level.
Set when Avg. Fiber Coupled Power exceeds the bytes 24-25 level.
Set when Avg. Fiber Coupled Power is below the bytes 26-27 level.
Set when Avg. Received Power exceeds the bytes 32-33 level.
Set when Avg. Received Power is below the bytes 34-35 level.
Reserved
Reserved
Set when internal temperature exceeds the bytes 4-5 level.
Set when internal temperature is below the bytes 6-7 level.
Set when TX VDD exceeds the bytes 12-13 level.
Set when TX VDD is below the bytes 14-15 level.
Set when Laser Diode Current exceeds the bytes 20-21 level.
Set when Laser Diode Current is below the bytes 22-23 level.
Set when Avg. Fiber Coupled Power exceeds the bytes 28-29 level.
Set when Avg. Fiber Coupled Power is below the bytes 30-31 level.
Set when Avg. Received Power exceeds the bytes 36-37 level.
Set when Avg. Received Power is below the bytes 38-39 level.
Reserved
Reserved
Vendor Specific
Description of Fields
October 2008