166981-005 FCI, 166981-005 Datasheet - Page 8

no-image

166981-005

Manufacturer Part Number
166981-005
Description
Manufacturer
FCI
Datasheet

Specifications of 166981-005

Lead Free Status / Rohs Status
Not Compliant
7.0
TITLE
Specification of Requirements for Cable Preparation, Wire Termination and
Copyright FCI
Form E-3334
Rev E
RECOMMENDED WIRE SIZES AND INSULATIONS
7.1
7.2
Assembly of Connectors Using 72392-type Contacts
No standard wiring diagram exists for the 88940 type Connectors
Wire Insulation Materials
Semi-rigid PVC , FEP, DP-3, PVC/PE, PTFE, PE, PP have been used.
Maximum Insulation Diameters and Wire Sizes
Certain stranded wires can be successfully inserted in the contact IDC but must be qualified individually.
The specification of the cable using the stranded wire must have the wire insulation type, wire insulation
thickness, number of strands, size of strands and twist of strands controlled.
30 gage solid
28 gage solid
26 gage solid
24 gage solid
Conductor
.3mm solid
.4mm solid
.5mm solid
Size
Figure 6 Wiring Diagram - 72477 Unshielded Connectors
TYPE
Insulation Thickness
APPLICATION SPECIFICATION
0.245
0.27
0.28
0.32
0.30
0.30
0.25
mm
Maximum Insulation Dimensions
0.011
0.011
0.013
0.012
0.012
0.010
0.010
inch
PDM: Rev:J
Insulation Diameter
0.80
0.86
0.96
1.00
1.00
1.00
1.00
mm
NUMBER
PAGE
AUTHORIZED BY
STATUS
STATUS:
0.032
0.034
0.038
0.040
0.040
0.040
0.040
J.R. Volstorf
inch
8 of 29
UNRESTRICTED
Released
GS-20-002
REVISION
DATE
25-Apr-06
Printed: Nov 27, 2010
J
GS-01-001
.