LH28F016SUT-10 Sharp Electronics, LH28F016SUT-10 Datasheet - Page 13

no-image

LH28F016SUT-10

Manufacturer Part Number
LH28F016SUT-10
Description
Manufacturer
Sharp Electronics
Datasheet

Specifications of LH28F016SUT-10

Cell Type
NOR
Density
16Mb
Access Time (max)
100ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
21/20Bit
Operating Supply Voltage (typ)
3.3/5V
Operating Temp Range
0C to 70C
Package Type
TSOP-I
Program/erase Volt (typ)
4.5 to 5.5V
Sync/async
Asynchronous
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3/4.5V
Operating Supply Voltage (max)
3.6/5.5V
Word Size
8/16Bit
Number Of Words
2M/1M
Supply Current
60mA
Mounting
Surface Mount
Pin Count
56
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LH28F016SUT-10
Manufacturer:
INTEL
Quantity:
5 510
Part Number:
LH28F016SUT-10
Manufacturer:
AUTONICS
Quantity:
5 510
16M (1M × 16, 2M × 8) Flash Memory
BLOCK STATUS REGISTER
BSR.7 = BLOCK STATUS (BS)
BSR.6 = BLOCK-LOCK STATUS (BLS)
BSR.5 = BLOCK OPERATION STATUS (BOS)
BSR.4 = BLOCK OPERATION ABORT STATUS (BOAS)
MATRIX 5/4
BSR.3 = QUEUE STATUS (QS)
BSR.2 = V
BS
7
1 = Ready
0 = Busy
1 = Block Unlocked for Write/Erase
0 = Block Locked for Write/Erase
1 = Operation Unsuccessful
0 = Operation Successful or Currently Running
1 = Operation Aborted
0 = Operation Not Aborted
00 = Operation Successful or Currently Running
01 = Not a valid Combination
10 = Operation Unsuccessful
11 = Operation Aborted
1 = Queue Full
0 = Queue Available
1 = V
0 = V
PP
STATUS (V
PP
PP
Low Detect, Operation Abort
OK
BLS
6
PPS
)
BOS
5
BOAS
4
NOTES:
1. RY
2. The BOAS bit will not be set until BSR.7 = 1.
3. Operation halted via Abort command.
4. BSR.1-0 = Reserved for future enhancements. These bits
5. When multiple operations are queued, checking BSR.7
completion of an operation (Block Lock, Suspend, Erase or
Data Write) before the appropriate Status bits (BOS, BLS)
is checked for success.
are reserved for future use; mask them out when polling
the BSRs.
only provides indication of completion for that particular
block. GSR.7 provides indication when all queued opera-
tions are completed.
QS
3
    »
/ BY
    »
output or BS bit must be checked to determine
VPPS
2
R
1
LH28F016SU
R
0
13