CY8C95xx Preliminary Data Sheet
Table 3-10. POR Defaults Data Structure
3.3.4
This command is used to read the POR settings stored in the
EEPROM.
To read POR defaults the user must:
August 17, 2005
00h – 07h
08h – 0Fh
10h – 17h
18h – 1Fh
20h – 27h
28h
29h
2Ah
2Bh
2Ch
2Dh
2Eh
2Fh – 35h
36h – 3Ch
3Dh – 43h
44h – 4Ah
4Bh – 51h
52h – 58h
59h – 5Fh
60h
61h
62h
63h – 65h
8Dh – 8Fh
90h
91h
92h
Write command 04h;
Read 146 data bytes (see
Read 1 CRC byte.
Offset
Read E2 POR Defaults Cmd (04h)
Output Port 0-7
Interrupt mask Port 0-7
Select PWM Port 0-7
Inversion Port 0-7
Pin Direction Port 0-7
Resistive pull up Drive Mode Port 0
Resistive pull down Drive Mode Port 0
Open drain high Drive Mode Port 0
Open drain low Drive Mode Port 0
Strong drive Drive Mode Port 0
Slow strong drive Drive Mode Port 0
High impedance Drive Mode Port 0
Drive Modes Port 1
Drive Modes Port 2
Drive Modes Port 3
Drive Modes Port 4
Drive Modes Port 5
Drive Modes Port 6
Drive Modes Port 7
Config setting PWM0
Period setting PWM0
Pulse Width setting PWM0
PWM1 settings
PWM15 settings
Divider
Enable
CRC
Table
3-10).
Value
Document No. 38-12036 Rev. *A
3.3.5
This command is used to send a new device configuration to
the CY8C95xx. It is followed by 146 data bytes according to
Table
bytes (00h-91h). If the CRC check fails or an incomplete block
is sent, then the slave will respond with a NAK and the device
will not use the data. This gives the user ‘flat-address-space’
access to all device settings.
To set the current device configuration the user must:
If the CRC check passes, then the device will use the new set-
tings immediately.
Content of the data block is described in
3.3.6
This command is used to read the current device configuration.
It gives the user ‘flat-address-space’ access to all device set-
tings.
To read device configuration the user must:
3.3.7
This command is used to immediately reconfigure the device
with actual POR defaults from EEPROM. It has the same effect
on the registers as a POR.
Write command 05h;
Write 146 data bytes with new values of registers;
Write 1 CRC byte calculated as XOR of previous 146 data
bytes.
Write command 06h;
Read 146 data bytes (see
Read 1 CRC byte.
3-10. The CRC is calculated as the XOR of the 146 data
Write Device Config Cmd (05h)
Reconfigure Device Cmd (07h)
Read Device Config Cmd (06h)
Table
3-10).