SI3201-KS Silicon Laboratories Inc, SI3201-KS Datasheet - Page 47

IC LINEFEED INTRFC SI321X 16SOIC

SI3201-KS

Manufacturer Part Number
SI3201-KS
Description
IC LINEFEED INTRFC SI321X 16SOIC
Manufacturer
Silicon Laboratories Inc
Series
ProSLIC®r
Datasheet

Specifications of SI3201-KS

Package / Case
16-SOIC (3.9mm Width) Exposed Pad, 16-eSOIC, 16-HSOIC
Function
CODEC
Interface
PCM, Serial, SPI
Number Of Circuits
1
Voltage - Supply
3.13 V ~ 5.25 V
Current - Supply
88mA
Power (watts)
800mW
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Includes
BORSCHT Functions, Ring Trip Detection
Product
SLIC
Supply Voltage (min)
3.13 V
Supply Current
88 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3201-KS
Manufacturer:
SILICON
Quantity:
18
Part Number:
SI3201-KS
Manufacturer:
SILICONIX
Quantity:
20 000
Part Number:
SI3201-KSR
Manufacturer:
ELANTEC
Quantity:
50 000
Part Number:
SI3201-KSR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
SI3201-KSR
Quantity:
194
The pulse metering oscillator has a volume envelope
(linear ramp) on the on/off transitions of the oscillator.
The volume value is incremented by the value in the
PLSD register (indirect Register 23) at an 8 kHz rate.
The sinusoidal generator output is multiplied by this
volume before being sent to the DAC. The volume will
ramp from 0 to 7FFF in increments of PLSD; so, the
value of PLSD will set the slope of the ramp. When the
pulse metering signal is turned off, the volume will ramp
to 0 by decrementing according to the value of PLSD.
Pulse Metering Oscillator
Pulse Metering Frequency
Coefficient
Pulse Metering Amplitude
Coefficient
Pulse Metering Attack/Decay
Ramp Rate
Pulse Metering Active Timer
Pulse Metering Inactive Timer
Pulse Metering Control
Note: The ProSLIC uses registers that are both directly and indirectly mapped. A direct register is one that is mapped
Figure 24. Pulse Metering Volume Envelope
8 Khz
directly. An indirect register is one that is accessed using the indirect access registers (direct registers 28
through 31).
Volum e
Parameter
Clip to 7FFF or 0
Table 33. Associated Pulse Metering Generator Registers
+/–
X
Status and control registers
0 to PLSX (full amplitude)
Sets oscillator frequency
Sets oscillator amplitude
Description / Range
0 to 8 seconds
0 to 8 seconds
To DAC
PLSD
Rev. 1.45
2.6. DTMF Detection
The dual-tone multi-frequency (DTMF) tone signaling
standard is also known as touch tone. It is an in-band
signaling system used to replace the pulse-dial
signaling standard. In DTMF, two tones are used to
generate a DTMF digit. One tone is chosen from four
possible row tones, and one tone is chosen from four
possible column tones. The sum of these tones
constitutes one of 16 possible DTMF digits.
2.6.1. DTMF Detection Architecture
DTMF detection is performed using a modified Goertzel
algorithm to compute the dual frequency tone (DFT) for
each of the eight DTMF frequencies as well as their
second harmonics. At the end of the DFT computation,
the squared magnitudes of the DFT results for the eight
DTMF fundamental tones are computed. The row
results are sorted to determine the strongest row
frequency; the column frequencies are sorted as well.
At the completion of this process, a number of checks
are made to determine whether the strongest row and
column tones constitute a DTMF digit.
The detection process is performed twice within the
45 ms minimum tone time. A digit must be detected on
two consecutive tests following a pause to be
recognized as a new digit. If all tests pass, an interrupt
is generated, and the DTMF digit value is loaded into
the DTMF register. If tones occur at the maximum rate
of 100 ms per digit, the interrupt must be serviced within
85 ms so that the current digit is not overwritten by a
new one. There is no buffering of the digit information.
PSTAT, PMAE,
Register Bits
PMIE, PMOE
PLSCO[15:0]
PLSX[15:0]
PLSD[15:0]
PAT[15:0]
PIT[15:0]
Si3210/Si3211
Direct Registers 44 & 45
Direct Register 46 & 47
Indirect Register 25
Indirect Register 24
Indirect Register 23
Direct Register 35
Location
47

Related parts for SI3201-KS