SI3201-KS Silicon Laboratories Inc, SI3201-KS Datasheet - Page 97

IC LINEFEED INTRFC SI321X 16SOIC

SI3201-KS

Manufacturer Part Number
SI3201-KS
Description
IC LINEFEED INTRFC SI321X 16SOIC
Manufacturer
Silicon Laboratories Inc
Series
ProSLIC®r
Datasheet

Specifications of SI3201-KS

Package / Case
16-SOIC (3.9mm Width) Exposed Pad, 16-eSOIC, 16-HSOIC
Function
CODEC
Interface
PCM, Serial, SPI
Number Of Circuits
1
Voltage - Supply
3.13 V ~ 5.25 V
Current - Supply
88mA
Power (watts)
800mW
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Includes
BORSCHT Functions, Ring Trip Detection
Product
SLIC
Supply Voltage (min)
3.13 V
Supply Current
88 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3201-KS
Manufacturer:
SILICON
Quantity:
18
Part Number:
SI3201-KS
Manufacturer:
SILICONIX
Quantity:
20 000
Part Number:
SI3201-KSR
Manufacturer:
ELANTEC
Quantity:
50 000
Part Number:
SI3201-KSR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
SI3201-KSR
Quantity:
194
Register 67. Automatic/Manual Control
Reset settings = 0001_1111
Name
Bit
Type
7
6
5
4
3
2
1
0
Bit
Reserved
MNDIF
MNCM
AORD
AOPN
Name
SPDS
AOLD
ABAT
D7
Read returns zero.
Common Mode Manual/Automatic Select.
0 = Automatic control.
1 = Manual control, in which TIP (forward) or RING (reverse) forces voltage to follow
VCM value.
Differential Mode Manual/Automatic Select.
0 = Automatic control.
1 = Manual control (forces differential voltage to follow VOC value).
Speed-Up Mode Enable.
0 = Speed-up disabled.
1 = Automatic speed-up.
Battery Feed Automatic/Manual Select (Si3211 only).
0 = Automatic mode disabled.
1 = Automatic mode enabled (automatic switching to low battery in off-hook state).
Automatic/Manual Ring Trip Detect.
0 = Manual mode.
1 = Enter off-hook active state automatically upon ring trip detect.
Automatic/Manual Loop Closure Detect.
0 = Manual mode.
1 = Enter off-hook active state automatically upon loop closure detect.
Power Alarm Automatic/Manual Detect.
0 = Manual mode.
1 = Enter open state automatically upon power alarm.
MNCM
R/W
D6
MNDIF
R/W
D5
SPDS
Rev. 1.45
R/W
D4
Function
ABAT
R/W
D3
AORD
R/W
D2
Si3210/Si3211
AOLD
R/W
D1
AOPN
R/W
D0
97