SC16C2550BIA44,512 NXP Semiconductors, SC16C2550BIA44,512 Datasheet - Page 21

IC UART DUAL W/FIFO 44-PLCC

SC16C2550BIA44,512

Manufacturer Part Number
SC16C2550BIA44,512
Description
IC UART DUAL W/FIFO 44-PLCC
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SC16C2550BIA44,512

Features
False-start Bit Detection
Number Of Channels
2, DUART
Fifo's
16 Byte
Voltage - Supply
3.5 V ~ 4.5 V
With Auto Flow Control
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
With Cmos
Yes
Mounting Type
Surface Mount
Package / Case
44-LCC (J-Lead)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
935274407512
SC16C2550BIA44
SC16C2550BIA44

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C2550BIA44,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
SC16C2550B_5
Product data sheet
7.6 Modem Control Register (MCR)
Table 16.
Table 17.
This register controls the interface with the modem or a peripheral device.
Table 18.
LCR[2]
0
1
1
LCR[1]
0
0
1
1
Bit
7:5
4
3
2
1
0
Symbol
MCR[7:5]
MCR[4]
MCR[3]
MCR[2]
MCR[1]
MCR[0]
LCR[2] stop bit length
LCR[1:0] word length
Modem Control Register bits description
Word length (bits)
5, 6, 7, 8
5
6, 7, 8
LCR[0]
0
1
0
1
5 V, 3.3 V and 2.5 V dual UART, 5 Mbit/s (max.), with 16-byte FIFOs
Description
reserved; set to ‘0’
Loopback. Enable the local Loopback mode (diagnostics). In this mode the
transmitter output (TX) and the receiver input (RX), CTS, DSR, CD and RI
are disconnected from the SC16C2550B I/O pins. Internally the modem
data and control pins are connected into a loopback data configuration
(see
fully operational. The Modem Control Interrupts are also operational, but
the interrupts’ sources are switched to the lower four bits of the Modem
Control. Interrupts continue to be controlled by the IER register.
OP2/INT enable
(OP1). OP1A/OP1B are not available as an external signal in the
SC16C2550B. This bit is instead used in the Loopback mode only. In the
Loopback mode, this bit is used to write the state of the modem RI
interface signal.
RTS
DTR
Rev. 05 — 12 January 2009
logic 0 = disable Loopback mode (normal default condition)
logic 1 = enable local Loopback mode (diagnostics)
logic 0 = forces INT (A, B) outputs to the 3-state mode and sets OP2 to a
logic 1 (normal default condition)
logic 1 = forces the INT (A, B outputs to the active mode and sets OP2 to
a logic 0
logic 0 = force RTS output to a logic 1 (normal default condition)
logic 1 = force RTS output to a logic 0
logic 0 = force DTR output to a logic 1 (normal default condition)
logic 1 = force DTR output to a logic 0
Word length (bits)
5
6
7
8
Figure
7). In this mode, the receiver and transmitter interrupts remain
Stop bit length (bit times)
1
1
2
1
2
SC16C2550B
© NXP B.V. 2009. All rights reserved.
21 of 43