STA540 STMicroelectronics, STA540 Datasheet - Page 17

IC AMP AUD DUAL/QUAD MULTIWATT15

STA540

Manufacturer Part Number
STA540
Description
IC AMP AUD DUAL/QUAD MULTIWATT15
Manufacturer
STMicroelectronics
Type
Class ABr
Datasheet

Specifications of STA540

Output Type
2-Channel (Stereo) or 4-Channel (Quad)
Max Output Power X Channels @ Load
38W x 2 @ 4 Ohm; 16W x 4 @ 4 Ohm
Voltage - Supply
8 V ~ 22 V
Features
Short-Circuit and Thermal Protection, Standby
Mounting Type
Through Hole
Package / Case
Multiwatt-15 (Vertical, Bent and Staggered Leads)
Amplifier Class
AB
No. Of Channels
4
Output Power
24W
Supply Voltage Range
8V To 22V
Thd + N
0.02% @ 4W, 4ohm, VS=14.4V
Load Impedance
8ohm
Operating Temperature Range
-40°C To +150°C
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-8880-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STA540
Manufacturer:
FOXCONN
Quantity:
2 300
Part Number:
STA540
Manufacturer:
ST
0
Part Number:
STA540
Manufacturer:
ST
Quantity:
20 000
Part Number:
STA540
0
Company:
Part Number:
STA540
Quantity:
6 500
Company:
Part Number:
STA540
Quantity:
6 500
Company:
Part Number:
STA540
Quantity:
10 000
Part Number:
STA540(ROSH)
Manufacturer:
ST
0
Part Number:
STA540P
Manufacturer:
ST
0
Part Number:
STA540S
Manufacturer:
ST
0
Part Number:
STA540SA
Manufacturer:
ST
Quantity:
12 000
Part Number:
STA540SA
Manufacturer:
ST
0
Part Number:
STA540SA
Manufacturer:
ST
Quantity:
20 000
Part Number:
STA540SAN
Manufacturer:
ST
Quantity:
20 000
STA540
6.7
6.7.1
6.7.2
Built–in protection
Diagnostic facilities (pin 10)
The STA540 is equipped with diagnostic circuitry that is able to detect the following events:
"
"
"
The event is signalled when the open collector output of pin 10 begins to sink current.
Short-circuit protection
Reliable and safe operation in the presence of all kinds of output short circuit is assured by
the built-in protection. As well as the AC/DC short circuit to GND and to VS, and across the
speaker, there is a soft short-circuit condition, which is signalled on pin 10 (DIAGNOSTICD)
during the turn-on phase, to verify output circuit integrity in order to ensure correct amplifier
operation.
This particular kind of protection acts in such a way as to prevent the device being turned on
(via pin ST-BY) when a resistive path (that is a DC path) less than 16 Ω exists between the
output and GND. This would avoid loud speaker damage should, for example, the output
coupling capacitor develop an internal short circuit.
As mentioned previously, it is important to limit the external current driving pin ST-BY
to 5 mA. The reason is that the associated circuitry is normally disabled with currents
greater than 5 mA.
The soft short-circuit protection is particularly attractive when, in the single-ended
configuration, one capacitor is shared between two outputs (see
Figure 23. Shared capacitor in single-ended configuration
clipping of the output signal,
thermal shutdown,
output fault:
short circuit to GND,
short circuit to VS,
soft short circuit at turn-on.
Figure
Practical information
23).
17/23