AT32UC3A464 Atmel Corporation, AT32UC3A464 Datasheet - Page 453
AT32UC3A464
Manufacturer Part Number
AT32UC3A464
Description
Manufacturer
Atmel Corporation
Datasheets
1.AT32UC3A0128.pdf
(377 pages)
2.AT32UC3A0128.pdf
(33 pages)
3.AT32UC3A0128.pdf
(159 pages)
4.AT32UC3A3128.pdf
(91 pages)
5.AT32UC3A3128.pdf
(1012 pages)
Specifications of AT32UC3A464
Flash (kbytes)
64 Kbytes
Pin Count
100
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
Hardware Qtouch Acquisition
No
Usb Transceiver
1
Usb Speed
Hi-Speed
Usb Interface
Device + OTG
Spi
6
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
2
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
128
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Timers
6
Output Compare Channels
6
Input Capture Channels
6
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
AT32UC3A464-CIUT
Manufacturer:
ATMEL
Quantity:
180
Part Number:
AT32UC3A464-CIUT
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Company:
Part Number:
AT32UC3A464-U
Manufacturer:
XILINX
Quantity:
1
Company:
Part Number:
AT32UC3A464S-U
Manufacturer:
ATMEL
Quantity:
551
- AT32UC3A0128 PDF datasheet
- AT32UC3A0128 PDF datasheet #2
- AT32UC3A0128 PDF datasheet #3
- AT32UC3A3128 PDF datasheet #4
- AT32UC3A3128 PDF datasheet #5
- Current page: 453 of 1012
- Download datasheet (16Mb)
22.8.6
22.8.6.1
22.8.6.2
22.8.6.3
32072G–11/2011
SMBus Mode
Packet Error Checking (PEC)
Timeouts
SMBALERT
SMBus mode is enabled by writing a one to the SMBus Mode Enable (SMEN) bit in CR. SMBus
mode operation is similar to I²C operation with the following exceptions:
Each SMBus transfer can optionally end with a CRC byte, called the PEC byte. Writing a one to
the Packet Error Checking Enable (PECEN) bit in CR enables automatic PEC handling in the
current transfer. The PEC generator is always updated on every bit transmitted or received, so
that PEC handling on following linked transfers will be correct.
In slave receiver mode, the master calculates a PEC value and transmits it to the slave after all
data bytes have been transmitted. Upon reception of this PEC byte, the slave will compare it to
the PEC value it has computed itself. If the values match, the data was received correctly, and
the slave will return an ACK to the master. If the PEC values differ, data was corrupted, and the
slave will return a NAK value. The SR.SMBPECERR bit is set automatically if a PEC error
occurred.
In slave transmitter mode, the slave calculates a PEC value and transmits it to the master after
all data bytes have been transmitted. Upon reception of this PEC byte, the master will compare
it to the PEC value it has computed itself. If the values match, the data was received correctly. If
the PEC values differ, data was corrupted, and the master must take appropriate action.
The PEC byte is automatically inserted in a slave transmitter transmission if PEC enabled when
NBYTES reaches zero. The PEC byte is identified in a slave receiver transmission if PEC
enabled when NBYTES reaches zero. NBYTES must therefore be set to the total number of
data bytes in the transmission, including the PEC byte.
The Timing Register (TR) configures the SMBus timeout values. If a timeout occurs, the slave
will leave the bus. The SR.SMBTOUT bit is also set.
A slave can get the master’s attention by pulling the SMBALERT line low. This is done by writing
a one to the SMBus Alert (SMBALERT) bit in CR. This will also enable address match on the
Alert Response Address (ARA).
3. Start the transfer by enabling the Peripheral DMA Controller to receive.
4. Wait for the Peripheral DMA Controller end-of-receive flag.
5. Disable the Peripheral DMA Controller.
• Only 7-bit addressing can be used.
• The SMBus standard describes a set of timeout values to ensure progress and throughput on
• Transmissions can optionally include a CRC byte, called Packet Error Check (PEC).
• A dedicated bus line, SMBALERT, allows a slave to get a master’s attention.
• A set of addresses have been reserved for protocol handling, such as Alert Response
the bus. These timeout values must be written to TR.
Address (ARA) and Host Header (HH) Address. Address matching on these addresses can
be enabled by configuring CR appropriately.
453
Related parts for AT32UC3A464
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
INTERVAL AND WIPE/WASH WIPER CONTROL IC WITH DELAY
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
Low-Voltage Voice-Switched IC for Hands-Free Operation
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
MONOLITHIC INTEGRATED FEATUREPHONE CIRCUIT
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
AM-FM Receiver IC U4255BM-M
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
Monolithic Integrated Feature Phone Circuit
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
Multistandard Video-IF and Quasi Parallel Sound Processing
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
High-performance EE PLD
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
8-bit Flash Microcontroller
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
2-Wire Serial EEPROM
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
U6046BREAR WINDOW HEATING TIMER / LONG-TERM TIMER
Manufacturer:
ATMEL Corporation
Datasheet: