AT89C51ED2 Atmel Corporation, AT89C51ED2 Datasheet - Page 58

no-image

AT89C51ED2

Manufacturer Part Number
AT89C51ED2
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT89C51ED2

Flash (kbytes)
64 Kbytes
Max. Operating Frequency
60 MHz
Cpu
8051-12C
Max I/o Pins
32
Spi
1
Uart
1
Sram (kbytes)
2
Eeprom (bytes)
2048
Self Program Memory
API
Operating Voltage (vcc)
2.7 to 5.5
Timers
4
Isp
UART
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51ED2
Manufacturer:
ALTERA
0
Part Number:
AT89C51ED2
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT89C51ED2-3CSIM
Manufacturer:
ATMEL
Quantity:
77 760
Part Number:
AT89C51ED2-3CSIM
Manufacturer:
SSG
Quantity:
100
Part Number:
AT89C51ED2-IM
Manufacturer:
ATMEL
Quantity:
116
Part Number:
AT89C51ED2-IM
Manufacturer:
S
Quantity:
20
Part Number:
AT89C51ED2-IM(QFP-64)
Manufacturer:
ATMEL
Quantity:
458
Part Number:
AT89C51ED2-RDRIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51ED2-RDRUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51ED2-RDTUM
Manufacturer:
ATMEL
Quantity:
19 090
Part Number:
AT89C51ED2-RDTUM
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
AT89C51ED2-RLTUM
Manufacturer:
ATMEL
Quantity:
13 400
Part Number:
AT89C51ED2-RLTUM
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
58
AT89C51RD2/ED2
Table 14-13. BDRCON Register
BDRCON - Baud Rate Control Register (9Bh)
Reset Value = XXX0 0000b
Not bit addressable
Number
Bit
7
-
7
6
5
4
3
2
1
0
Mnemonic
RBCK
TBCK
BRR
SRC
SPD
6
Bit
-
-
-
-
Description
Reserved
The value read from this bit is indeterminate. Do not set this bit
Reserved
The value read from this bit is indeterminate. Do not set this bit
Reserved
The value read from this bit is indeterminate. Do not set this bit.
Baud Rate Run Control bit
Cleared to stop the internal Baud Rate Generator.
Set to start the internal Baud Rate Generator.
Transmission Baud rate Generator Selection bit for UART
Cleared to select Timer 1 or Timer 2 for the Baud Rate Generator.
Set to select internal Baud Rate Generator.
Reception Baud Rate Generator Selection bit for UART
Cleared to select Timer 1 or Timer 2 for the Baud Rate Generator.
Set to select internal Baud Rate Generator.
Baud Rate Speed Control bit for UART
Cleared to select the SLOW Baud Rate Generator.
Set to select the FAST Baud Rate Generator.
Baud Rate Source select bit in Mode 0 for UART
Cleared to select F
Set to select the internal Baud Rate Generator for UARTs in mode 0.
5
-
BRR
OSC
4
/12 as the Baud Rate Generator (F
TBCK
3
RBCK
2
CLK PERIPH
SPD
1
/6 in X2 mode).
4235K–8051–05/08
SRC
0