P87C554 NXP Semiconductors, P87C554 Datasheet - Page 50

The P87C554 Single-Chip 8-Bit Microcontroller is manufactured inan advanced CMOS process and is a derivative of the 80C51microcontroller family

P87C554

Manufacturer Part Number
P87C554
Description
The P87C554 Single-Chip 8-Bit Microcontroller is manufactured inan advanced CMOS process and is a derivative of the 80C51microcontroller family
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
P87C554SBAA
Quantity:
160
Part Number:
P87C554SBAA,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
P87C554SBAAЈ¬512
Manufacturer:
NXP
Quantity:
188
Part Number:
P87C554SBBD
Manufacturer:
TQS
Quantity:
1
Part Number:
P87C554SFAA
Manufacturer:
FSC
Quantity:
3 000
Part Number:
P87C554SFAA,512
Manufacturer:
Maxim
Quantity:
145
Part Number:
P87C554SFAA,512
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
P87C554SFAAЈ¬512
Manufacturer:
PH3
Quantity:
468
Company:
Part Number:
P87C554SFBD
Quantity:
542
Part Number:
P87C554X2
Manufacturer:
PHI
Quantity:
20 000
Company:
Part Number:
P87C554X2
Quantity:
108
Philips Semiconductors
I
An I
uncontrolled source. If the SCL line is obstructed (pulled LOW) by a
device on the bus, no further serial transfer is possible, and the
SIO1 hardware cannot resolve this type of problem. When this
occurs, the problem must be resolved by the device that is pulling
the SCL bus line LOW.
If the SDA line is obstructed by another device on the bus (e.g., a
slave device out of bit synchronization), the problem can be solved
by transmitting additional clock pulses on the SCL line (see Figure
46). The SIO1 hardware transmits additional clock pulses when the
STA flag is set, but no START condition can be generated because
the SDA line is pulled LOW while the I
The SIO1 hardware attempts to generate a START condition after
every two additional clock pulses on the SCL line. When the SDA
line is eventually released, a normal START condition is transmitted,
state 08H is entered, and the serial transfer continues.
If a forced bus access occurs or a repeated START condition is
transmitted while SDA is obstructed (pulled LOW), the SIO1
2002 Mar 25
2
C B
80C51 8-bit microcontroller – 12 clock operation
16K/512 OTP/RAM, 8 channel 10-bit A/D, I
capture/compare, high I/O
2
C bus hang-up occurs if SDA or SCL is pulled LOW by an
US
O
BSTRUCTED BY A
08H
S
STO FLAG
STA FLAG
SDA LINE
SCL LINE
SLA
L
OW
L
W
EVEL ON
Figure 44. Simultaneous Repeated START Conditions from 2 Masters
18H
2
A
C bus is considered free.
SCL
TIME LIMIT
OR
Figure 45. Forced Access to a Busy I
SDA
DATA
OTHER MASTER SENDS REPEATED
START CONDITION EARLIER
2
28H
A
C, PWM,
48
S
hardware performs the same action as described above. In each
case, state 08H is entered after a successful START condition is
transmitted and normal serial transfer continues. Note that the CPU
is not involved in solving these bus hang-up problems.
B
A bus error occurs when a START or STOP condition is present at
an illegal position in the format frame. Examples of illegal positions
are during the serial transfer of an address byte, a data or an
acknowledge bit.
The SIO1 hardware only reacts to a bus error when it is involved in
a serial transfer either as a master or an addressed slave. When a
bus error is detected, SIO1 immediately switches to the not
addressed slave mode, releases the SDA and SCL lines, sets the
interrupt flag, and loads the status register with 00H. This status
code may be used to vector to a service routine which either
attempts the aborted serial transfer again or simply recovers from
the error condition as shown in Table 10.
US
E
OTHER MST
CONTINUES
RROR
START CONDITION
2
C Bus
P
RETRY
08H
S
SLA
SU00976
SU00975
P87C554
Product data

Related parts for P87C554