TLE 8264-2E Infineon Technologies, TLE 8264-2E Datasheet - Page 15

no-image

TLE 8264-2E

Manufacturer Part Number
TLE 8264-2E
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE 8264-2E

Packages
PG-DSO-36
Transceiver
High Speed CAN ISO 11898 - 5 / 3 x LIN2.0 / J2602
Voltage Regulator Output
2 x 200 mA + 400 mA
Watchdog
Standard and Window Watchdog
Quiescent Current (max.)
28 ?A (typ) Sleep Mode (5V on)
Standby Current
58 ?A (typ) Stop Mode (5V on)
4.2.9
In SBC Fail-Safe Mode, all voltage regulators are OFF and the transceivers are in Wake-Capable Mode. The Limp
Home output is active.
Conditions to enter the SBC Fail-Safe Mode are:
In case of
and will go back to SBC Restart Mode.
In case of a wake-up event, the SBC will go to SBC Restart Mode (not in case of
shutdown), storing the wake-up event and resetting the Watchdog trigger failure counter. The first SPI output data
when going to SBC Normal Mode will always indicate the reason for the SBC Fail-Safe Mode.
4.2.10
If the Test pin is connected to GND (Config 0 active) during powering-up, the SBC enters SBC Software
Development Mode. SBC Software Development Mode is a super set of the other modes so it is possible to use
all the modes of the SBC with the following difference. In SBC Software Development Mode, no reset is generated
and
indicated by the INT output (reset bit). The SBC Fail-Safe Mode or SBC Restart Mode are not reached in case of
wrong Watchdog trigger but the other reasons to enter these modes are still valid.
4.2.11
In this mode, the SBC is completely powered OFF and the microcontroller is supplied externally. The mode is
detected when
flow out of
maximum rating stated in
resistor.
Note: Please respect the absolute maximum ratings when the device is in SBC Factory Flash Mode.
Data Sheet
Watchdog trigger failure in configuration 2 or 4
V
Temperature shutdown of
Reset clamped in Config. 2/4
V
cc1µC
CC1µC
V
undervoltage time-out in any configuration if
V
cc1µC
is not switched off due to Watchdog trigger failure. If a Watchdog trigger failure occurs, it will be
s
SBC Fail-Safe Mode
SBC Software Development Mode
SBC Factory Flash Mode
must be limited to the maximum rating. The external supply voltage should be below the absolute
V
overtemperature shutdown, the SBC will latch and wait to cool down below the thermal hysteresis,
CC1µC
is powered from external and the voltage on
Chapter
V
cc1µC
5.1. The reset can be driven by an external circuit, or pulled high with a pull-up
in any configuration.
V
15
S
is above
V
V
LHUV
s
is not powered from external. The current
range.
V
cc1µC
Rev. 1.0, 2009-03-31
overtemperature
TLE8264-2E
State Machine

Related parts for TLE 8264-2E