STPIC44L02 STMicroelectronics, STPIC44L02 Datasheet - Page 4

no-image

STPIC44L02

Manufacturer Part Number
STPIC44L02
Description
4 CHANNEL SERIAL AND PARALLEL LOW SIDE PRE-FET DRIVER
Manufacturer
STMicroelectronics
Datasheet
www.DataSheet4U.com
STPIC44L02
PIN DESCRIPTION
4/21
PIN No
10
12
13
14
16
19
21
15
17
18
20
22
23
24
11
1
2
3
4
5
6
7
8
9
VCOMPEN
SYMBOL
VCOMP
DRAIN0
DRAIN1
DRAIN2
DRAIN3
RESET
GATE0
GATE1
GATE2
GATE3
SCLK
SDO
GND
V
V
FLT
SDI
IN0
IN1
IN2
IN3
CS
NC
BAT
CC
I/O
O
O
I
I
I
I
I
I
I
I
I
I
I
I
Fault Flag. FLT is a logic level open-drain output that provides a real time fault flag for
shorted-load, open-load, over-battery voltage, under-battery voltage faults. The
device can be ORed with FLT terminals on other devices for interrupt handling. FLT
requires an external pull-up resistor.
Fault reference voltage select. VCOMPEN selects the internally generated fault
reference voltage (0) or an external fault reference (1) to be used in the shorted and
open load fault detection circuitry.
Fault reference voltage. VCOMP provides an external fault reference voltage for the
shorted-load and open load fault detection circuitry.
Parallel gate driver. IN0 trough In3 are real-time controls for the gate pre drive
circuitry. They are CMOS compatible with hysteresis.
Chip select. A high to low transition on CS enables SDO, latches fault data into the
serial interface, and refreshes FLT. When CS is high, the fault register can change
fault status. On the falling edge of CS, fault data is latched into the serial output
register and transferred using SDO and SCLK. On a low to high transition of CS,
serial data is latched in to the output control register.
Serial data output. SDO is a 3-state output that transfers fault data to the controlling
device. It also passes serial input data to the next stage for cascaded operation. SDO
is taken to a high-impedance state when CS is in a high state.
Serial data input. Output control data is clocked into the serial register through SDI. A
1 on SDI commands a particular gate output on and a 0 turns it off.
Serial clock. SCLK clocks the shift register. Serial data is clocked into SDI and serial
fault data is clocked out of SDO on the falling edge of the serial clock.
Logic Supply Voltage
Ground
FET drain inputs. DRAIN0 through DRAIN3 are used for both open load and short
circuit fault detection at the drain of the external FETs. They are also used for
inductive transient protection.
Gate drive output. GATE0 through GATE3 outputs are derived from the V
voltage. Internal clamps prevent voltages on these nodes from exceeding the VGS
rating of most FETs.
Reset. A high-to low transition of RESET clears all registers and flags. Gate outputs
turn off and the FLT flag is cleared.
Not Connected
Battery Supply Voltage
NAME AND FUNCTION
BAT
supply

Related parts for STPIC44L02