S2053 AMCC (Applied Micro Circuits Corp), S2053 Datasheet - Page 3

no-image

S2053

Manufacturer Part Number
S2053
Description
Bicmos Lvpecl Clock Generator Fibre Channel And Gigabit Ethernet Transceiver
Manufacturer
AMCC (Applied Micro Circuits Corp)
Datasheet
TRANSMITTER FUNCTIONAL
DESCRIPTION
The S2053 transmitter accepts parallel input data and
serializes it for transmission over fiber optic or coaxial
cable media. The chip is fully compatible with the ANSI
X3T11 Fibre Channel standard, and supports the Fi-
bre Channel Gigabit Ethernet standard’s data rates of
1250 and 1062 Mbit/sec. (See Figure 3.)
Parallel/Serial Conversion
The parallel-to-serial converter takes in 10-bit wide
data from the input latch and converts it to a serial
data stream. Parallel data is latched into the transmitter
on the positive going edge of the reference clock.
The data is then clocked synchronous to the clock
synthesis unit serial clock into the serial output shift
register. The shift register is clocked by the internally
generated bit clock which is 10x of the reference clock
inputfrequency. D0 is transmitted first as described in
annex N and Tables 22 and 23 of FC-PH. Table 1
shows the mapping of the parallel data to the 8B/10B
codes.
Reference Clock Input (Transmit Byte Clock)
The reference clock input must be supplied with a
clock source with 100 PPM tolerance to assure that
the transmitted data meets the Fibre Channel frequency
limits. The internal serial clock is frequency locked to the
reference clock (125.00 and 106.25 MHz).
Figure 4. Functional Waveform (1250 and 1062.5 Mbit/sec)
FIBRE CHANNEL AND GIGABIT ETHERNET TRANSCEIVER
INPUT TIMING
OUTPUT TIMING
PARALLEL
DATA BUS
(Output)
REFCLKP/N
TREFCLK
(Input)
SERIAL DATA
RBC0
(Output)
RBC1
(Output)
COM_DET
(Output)
PARALLEL
DATA BUS
(Input)
K28.5
K28.5
K28.5
Byte 1
RECEIVER FUNCTIONAL DESCRIPTION
The S2053 receiver is designed to implement the ANSI
X3T11 Fibre Channel specification and the IEEE 802.3z
Gigabit Ethernet receiver functions. A block diagram
showing the basic chip function is provided in Figure 3.
Whenever a signal is present, the S2053 attempts to
achieve synchronization on both bit and transmission-
word boundaries of the received encoded bit stream.
Received data from the incoming bit stream is pro-
vided on the device’s parallel data outputs.
The S2053 accepts serial encoded data from a fiber
optic or coaxial cable interface. The serial input stream is
the result of the serialization of 8B/10B encoded data by
an FC compatible transmitter. Clock recovery is performed
on-chip, with the output data presented to the Fibre
Channel transmission layer as 10-bit parallel data.
Table 1. Data Mapping to 8b/10b
TX[0:9] or
RX[0:9]
8b/10b alphabetic
representation
Byte 2
Alphabetic Representation
K28.5
Byte 3
0
a
1
b
Byte 4
K28.5
2
c
3
d
Byte 5
Data Byte
4
e
5
i
K28.5
6
f
7
g
S2053
8
h
9
j
3

Related parts for S2053