AC04 ETC, AC04 Datasheet - Page 23

no-image

AC04

Manufacturer Part Number
AC04
Description
Cemented Wirewound Resitors
Manufacturer
ETC
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AC04
Manufacturer:
MOTOROLA
Quantity:
9
Part Number:
AC04
Manufacturer:
ST
0
Company:
Part Number:
AC04000001001JAC00
Quantity:
70 000
Company:
Part Number:
AC04000001001JAC00
Quantity:
70 000
Part Number:
AC04000002208JAC00
Manufacturer:
Vishay
Quantity:
572
Part Number:
AC04000003308JAC00
Manufacturer:
Vishay
Quantity:
500
Company:
Part Number:
AC04000003900JAC00
Quantity:
70 000
Part Number:
AC0402FR-07100KL
Manufacturer:
YAGEO/国巨
Quantity:
20 000
Company:
Part Number:
AC0402FR-07100RL
Quantity:
8 292
Part Number:
AC0402FR-0710KL
Manufacturer:
YAGEO
Quantity:
64 000
Part Number:
AC0402FR-0710RL
Manufacturer:
YAGEO
Quantity:
64 000
Part Number:
AC0402FR-0712K4L
Manufacturer:
YAGEO/国巨
Quantity:
20 000
Part Number:
AC0402FR-07200RL
Manufacturer:
YAGEO/国巨
Quantity:
20 000
Part Number:
AC0402FR-0722KL
Manufacturer:
YAGEO原装
Quantity:
20 000
Part Number:
AC0402FR-0733KL
Manufacturer:
YAGEO/国巨
Quantity:
20 000
Company:
Part Number:
AC0402FR-0782R5L
Quantity:
40 000
BCcomponents
TESTS AND REQUIREMENTS
Essentially all tests are carried out in accordance with the
schedule of “IEC publications 60115-1 and 60115-4”,
category 40/200/56 (rated temperature range 40 C to
+200 C; damp heat, long term, 56 days). The testing also
covers the requirements specified by EIA and EIAJ.
The tests are carried out in accordance with IEC publication
60 068, “Recommended basic climatic and mechanical
robustness testing procedure for electronic components”
and under standard atmospheric conditions according to
“IEC 60 068-1”, subclause 5.3.
Table 5
2000 Oct 20
Tests in accordance with the schedule of IEC publication 60115-1
4.15
4.16
4.17
4.18
4.19
4.22
4.20
60115-1
CLAUSE
Cemented wirewound resistors
IEC
Test procedures and requirements
METHOD
U
Ua
Ub
Uc
Ta
Tb
14 (Na)
Fc
Eb
60068
TEST
IEC
robustness of
resistor body
robustness of
terminations:
solderability
resistance to soldering
heat
rapid change of
temperature
vibration
bump
tensile all samples
bending half
number of samples
torsion other half of
samples
TEST
load 200 10 N
load 10 N; 10 s
load 5 N 90 , 180 , 90
2
2 s; 235 C; flux 600
thermal shock: 3 s; 350 C;
2.5 mm from body
30 minutes at 40 C and
30 minutes at +200 C; 5 cycles
frequency 10 to 500 Hz; displacement
0.75 mm or acceleration 10 g;
3 directions; total 6 hours (3
4000 10 bumps; 390 m/s
180 in opposite directions
23
In Table 5 the tests and requirements are listed with
reference to the relevant clauses of
“IEC publications 60115-1, 115-4 and 68” ; a short
description of the test procedure is also given. In some
instances deviations from the IEC recommendations were
necessary for our method of specifying.
All soldering tests are performed with mildly activated flux.
PROCEDURE
load
AC01/03/04/05/07/10/15/20
R = 6 mm
2
MBB179
2 hours)
no visible damage
no visible damage
good tinning; no damage
no visible damage
no damage
no damage
R/R max.: 0.5% + 0.05
R/R max.: 0.5% + 0.05
R/R max.: 0.5% + 0.05
R/R max.: 1% + 0.05
R/R max.: 0.5% + 0.05
R/R max.: 0.5% + 0.05
REQUIREMENTS
Product specification

Related parts for AC04