The following defines the features of the I
col:
(1) Data transfer may be initiated only when the bus is
(2) During a data transfer, the data line must remain
The START Condition precedes all commands to the
device, and is defined as a HIGH to LOW transition of
SDA when SCL is HIGH. The CAT24FC01 monitors the
SDA and SCL lines and will not respond until this
condition is met.
A LOW to HIGH transition of SDA when SCL is HIGH
determines the STOP condition. All operations must end
with a STOP condition.
The Master begins a transmission by sending a START
condition. The Master then sends the address of the
particular slave device it is requesting. The four most
significant bits of the 8-bit slave address are fixed as
1010 for the CAT24FC01 (see Fig. 5). The next three
significant bits (A2, A1, A0) are the device address bits
not busy.
stable whenever the clock line is high. Any changes
in the data line while the clock line is high will be
interpreted as a START or STOP condition.
FROM TRANSMITTER
FROM RECEIVER
DATA OUTPUT
DATA OUTPUT
SCL FROM
MASTER
1
START
0
1
2
C bus proto-
0
1
DEVICE ADDRESS
A2
5
A1
and define which device the Master is accessing. Up to
eight CAT24FC01 may be individually addressed by the
system. The last bit of the slave address specifies
whether a Read or Write operation is to be performed.
When this bit is set to 1, a Read operation is selected,
and when set to 0, a Write operation is selected.
After the Master sends a START condition and the slave
address byte, the CAT24FC01 monitors the bus and
responds with an acknowledge (on the SDA line) when
its address matches the transmitted slave address. The
CAT24FC01 then performs a Read or a Write operation
depending on the state of the R/W bit.
After a successful data transfer, each receiving device is
required to generate an acknowledge. The Acknowledg-
ing device pulls down the SDA line during the ninth clock
cycle, signaling that it received the 8 bits of data.
The CAT24FC01 responds with an acknowledge after
receiving a START condition and its slave address. If the
device has been selected along with a write operation,
it responds with an acknowledge after receiving each
byte.
When the CAT24FC01 begins a READ mode, it trans-
mits 8 bits of data, releases the SDA line, and monitors
the line for an acknowledge. Once it receives this ac-
knowledge, the CAT24FC01 will continue to transmit
data. If no acknowledge is sent by the Master, the device
terminates data transmission and waits for a STOP
condition.
A0
R/W
Normal Read and Write
8
ACKNOWLEDGE
9
Doc No. 1073, Rev. D