uja1061 NXP Semiconductors, uja1061 Datasheet - Page 41

no-image

uja1061

Manufacturer Part Number
uja1061
Description
Low Speed Can/lin System Basis Chip
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
uja1061/3V3
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
uja1061/5V0
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
uja1061/5VO
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
uja1061TW/3V0
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
uja1061TW/5V0
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
uja1061TW/5V0/C/T
Manufacturer:
NXP
Quantity:
8 000
NXP Semiconductors
Table 20.
Table 21.
UJA1061_5
Product data sheet
Symbol
GSTHC
RLC
V3C
V1CMC
WEN
WSC
ILEN
ILC
Symbol
V2C
CPNC
COTC
CTC
CRC
CMC
LMC
LSC
LDC
LWEN
LTC
System Configuration register and System Configuration Feedback register: status at reset
Physical Layer Control register and Physical Layer Control Feedback register: status at reset
Name
GND Shift level
Threshold Control
Reset Length
Control
V3 Control
V1 Current Monitor
Control
Wake Enable
Wake Sample
Control
INH/LIMP Enable
INH/LIMP Control
Name
V2 Control
CAN Partial
Networking Control
CAN Off-line Time
Control
CAN Transmitter
Control
CAN Receiver
Control
CAN Mode Control 0 (Active mode
LIN Mode Control
LIN Slope Control
LIN Driver Control
LIN Wake-up
Enable
LIN Transmitter
Control
Power-on
0 (normal)
0 (short)
00 (off)
0 (watchdog
restart)
1 (enabled)
0 (control)
0 (floating)
0 (LOW)
Power-on
0 (auto)
0 (On-line Listen
mode disabled)
1 (long)
0 (on)
0 (normal)
disabled)
0 (Active mode
disabled)
0 (normal)
0 (LIN 2.0)
1 (enabled)
0 (on)
Rev. 05 — 22 November 2007
Start-up
no change
no change
no change
no change
no change
no change
see
ILC = 1, otherwise
no change
no change
Start-up
no change
0 if reset is caused
by a CAN wake-up,
otherwise no
change
no change
no change
no change
no change
no change
no change
no change
no change
no change
Fault-tolerant CAN/LIN fail-safe system basis chip
Figure 12
if
Restart
no change
1 (long)
no change
no change
no change
no change
0 (floating) if
ILC = 1, otherwise
no change
no change
Restart
no change
no change
no change
no change
no change
no change
no change
no change
no change
no change
no change
© NXP B.V. 2007 Nov 23. All rights reserved.
UJA1061
Fail-safe
no change
1 (long)
no change
no change
no change
no change
1 (active)
0 (LOW)
Fail-safe
0 (auto)
0 (On-line Listen
mode disabled)
no change
no change
no change
no change
no change
no change
no change
no change
no change
41 of 74