mic3003gfltr Micrel Semiconductor, mic3003gfltr Datasheet - Page 72

no-image

mic3003gfltr

Manufacturer Part Number
mic3003gfltr
Description
Fom Management Ic With Internal Calibration
Manufacturer
Micrel Semiconductor
Datasheet
Micrel, Inc.
July 2010
Default values
Serial address
Byte addresses
These registers hold the slope and offset coefficients used to calibrate the MIC3003’s ADC results in internal calibration mode.
Note that the temperature offset is also used in external calibration mode; but this can be disabled in OEMCFG5 (or by setting
the offset coefficient to zero).
These registers are non-volatile and will be maintained through power and reset cycles. A valid OEM password is required for
access to these registers.
Default value
Serial address
Byte address
The value in this register, in combination with the DEV_ID register, serves to identify the MIC3003 and its revision number to
software.
This register is read-only.
D[7:0]
Address
Bit(s)
74 (4Ah)
75 (4Bh)
76 (4Ch)
77 (4Dh)
78 (4Eh)
read-only
79 (4Fh)
80 (50h)
81 (51h)
82 (52h)
83 (53h)
84 (54h)
85 (55h)
86 (56h)
87 (57h)
D[7]
A6
Function
Identifies Micrel as the manufacturer of the device. Always
returns 2A h .
TXOFFh
VSLP0h
TXSLPh
VOFF0l
TXOFFl
TOFF0l
VSLP0l
ISLP0h
TXSLPl
TOFFh
VOFFh
IOFF0l
read-only
ISLP0l
IOFFh
Bytes
D[6]
Identifies Micrel as the manufacturer of the device. Always returns 2Ah
Temperature offset (six-bit signed offset, .5 C resolution)
Not used
Voltage slope, high byte
Voltage slope, low byte
Voltage offset, high byte
Voltage offset, low byte
Bias current slope, high byte
Bias current slope, low byte
Bias current offset, high byte
Bias current offset, low byte
TX Power slope, high byte
TX Power slope, low byte
TX Power offset, high byte
TX Power offset, low byte
read-only
D[5]
Calibration Constants (CALCOEFn)
Manufacturer ID Register (MFG_ID)
Offset coefficients are set to a default value of zero
Slope coefficients are set to a default value of 1.0
A6 h
74 - 87 = 4Ah - 57h
0010 1010 b = 2A h
A6 h
254 = FE h
read-only
D[4]
read-only
72
D[3]
Definition
Read-only. Always returns A h
Operation
read-only
D[2]
hbwhelp@micrel.com
read-only
D[1]
or (408) 955-1690
M9999-072910-A
read-only
MIC3003GFL
D[0]

Related parts for mic3003gfltr