pdiusbh11 NXP Semiconductors, pdiusbh11 Datasheet - Page 13

no-image

pdiusbh11

Manufacturer Part Number
pdiusbh11
Description
Universal Serial Bus Hub
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
pdiusbh11AD
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Company:
Part Number:
pdiusbh11AD
Quantity:
384
Part Number:
pdiusbh11ANB
Manufacturer:
PHI
Quantity:
6 240
Part Number:
pdiusbh11ANB
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
pdiusbh11D
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
pdiusbh11NB
Manufacturer:
PHILIPS
Quantity:
80
Part Number:
pdiusbh11NB
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Philips Semiconductors
Hub Commands
Hub commands are used to report connectivity and power status between the hub and the host. These commands allow the host to enable
each port individually and get any change of status such as new connectivity information.
Clear/Set Port Feature
Command
Data
When the controller receives a Set Feature or a Clear Feature request, there are two possibilities:
When the PDIUSBH11 is configured in mode 0, there is only one power switch output and one overcurrent input. This means that the
F_PORT_POWER and C_PORT_OVERCURRENT features are not port specific. For these features, any of the Set / Clear Feature commands
can be used. The specific port assignment is ignored.
When the PDIUSBH11 is configured in mode 1, there is still only one power switch output but there are four individual overcurrent input pins
corresponding to each port. This means that the F_PORT_POWER feature is port specific and the C_PORT_OVERCURRENT feature is not
port specific.
Setting the F_PORT_POWER feature turns the power on when it is off and turns the overcurrent detection on only when the power is already
on. This allows to have a short period of overcurrent condition at the moment that power is switched on. For this reason, the F_PORT_POWER
feature needs to be set twice. Clearing this feature turns both the power and the overcurrent detection off.
The data written in the data phase is the feature code described in Table 2.
Table 2.
1997 Aug 01
FEATURE
F_PORT_ENABLE
F_PORT_SUSPEND
FC_PORT_RESET
F_PORT_POWER
C_PORT_CONNECTION
C_PORT_ENABLE
C_PORT_SUSPEND
C_PORT_OVERCURRENT
The request applies to port 1, the embedded port. In this case the request should be handled internally by the controller.
If the request applies to ports 2 through 5, the controller should translate the request into a Set Feature or Clear Feature command towards
the PDIUSBH11.
Universal Serial Bus Hub
: E0–E3h (Clear) and E8h–EBh (Set)
: Write 1 byte
FEATURE CODE
0
1
2
3
4
5
6
7
SET
Enables a port
Suspends a port
Resets a port
Powers all ports
13
CLEAR
Disables a port
Resumes a port
Clears a port Reset Change bit
Unpowers all ports
Clears a port Connection Change bit
Clears a port Enable Change bit
Clears a port Suspend Change bit
Clears a port (Mode 1) or hub (Mode 0) Overcurrent Change bit
PDIUSBH11
Product specification

Related parts for pdiusbh11