2—SOFTWARE
CMT
Cut time_length units, in 10 ms segments, off the end of the current message. The maximum value of
time_length is 6550. In case of silence, cut-time accuracy is 0.1 to 0.2 seconds (depends on compres-
sion rate).
If time_length is greater than 6550 the ERR-PARAM is set in the ERR_WORD.
NOTE
Example
CVOC
Checks (checksum) if the IVS data of the currently selected vocabulary was correctly programmed to the
ROM or Flash device.
If the vocabulary data is correct the return value is 1. Otherwise the return value is 0.
If the current vocabulary is undefined, ERR_INVALID is reported.
Example
ISD
CMT 02BC
Byte sequence:
Description:
CVOC
Byte sequence:
Description:
If time_length is longer than the total duration of the message, the EV_NORMAL_END event is set
in the status word and the message becomes empty but not deleted.
A compressed frame represents 21 ms of speech, thus the minimum meaningful parameter is 3,
(i.e., a 30 ms cut).
CMT 1 or CMT 2 have no effect.
The CMT command can not be used on data messages.
In PCM recording mode the accuracy of
of linear configuration is 0.25 sec.
Use the DM (Delete Message), or DMS (Delete Messages) command to delete the message.
Microcontroller
VoiceDSP
Cut the last seven seconds of the current message.
Microcontroller
VoiceDSP
Check the current vocabulary.
The VoiceDSP processor responds that the vocabulary is OK.
Cut Message Tail time_length
Check Vocabulary
µ-,
A-Law configuration is 0.50 sec while the accuracy
26
26
2B
2B
02
02
ISD-T360SB
AA
01
BC
BC
2-29