mk50h27 STMicroelectronics, mk50h27 Datasheet - Page 29

no-image

mk50h27

Manufacturer Part Number
mk50h27
Description
Signalling System 7 Link Controller
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mk50h27N
Manufacturer:
ST
Quantity:
20 000
Part Number:
mk50h27Q-10
Manufacturer:
ST
Quantity:
12 388
Part Number:
mk50h27Q-10
Manufacturer:
ST
0
Part Number:
mk50h27Q-25
Manufacturer:
ST
Quantity:
12 388
Part Number:
mk50h27Q-25
Manufacturer:
ST
0
Part Number:
mk50h27Q-33
Quantity:
3 710
Part Number:
mk50h27Q-33
Manufacturer:
ST
0
Part Number:
mk50h27Q-33/25/16
Manufacturer:
ST
0
Part Number:
mk50h27Q33B
Manufacturer:
NIC
Quantity:
2 028
Part Number:
mk50h27Q33B
Manufacturer:
STMicroelectronics
Quantity:
10 000
4.2.3 Protocol Parameters
PARM
PO
DESCRIPTION
PROTOCOL OPTIONS. Defines the SS7 protocol options to be used.
BIT
00
01
02
03
04
05
06
07
08
15-09
IADR + 26
IADR + 28
IADR + 30
IADR + 32
IADR + 34
ANSIT6/T7 Selects ANSI or ITU compliance for SS7 T6 & T7 timers
NAME
DBUSY DBUSY = 1: Disables busy mechanisms on both transmit and receive.
XYEL
RYEL
RMODE Defines the retransmission method to be used.
BECDOUBLE Provides double transmission of all MSUs in BEC. All MSU’s
ERMEN Enables the AERM and SUERM error rate monitors.
OCTEN Enables octet counting.
2/3EN
Missed MSU interrupts (CSR0<06>, MISS) are not affected by this bit.
XYEL= 0: Transmitted SINs and SIEs conform to CCITT
Red/Blue Book definitions (SF = 1 and 2 respectively). XYEL= 1:
Transmitted SINs and SIEs conform to CCITT Yellow Book defini-
tions (SF = 9 & 10 respectively).
RYEL= 0: Only CCITT Red/Blue Book definitions for received SINs
and SIEs are accepted.
RYEL= 1: Either CCITT Yellow or Red/Blue Book definitions for re-
ceived SINs and SIEs are accepted.
RMODE = 0: specifies Basic Error Recovery (BEC).
RMODE = 1: specifies Preventive Cyclic Redundancy(PCR).
including those sent during negative acknowledgement are transmit-
ted twice. If RMODE= 0 then the following definitions apply:
BECDOUBLE = 0: specifies normal BEC.
BECDOUBLE = 1: specifies BEC with doubletransmission.
NOTE: BECDOUBLE must be 0 if RMODE = 1.
ERMEN = 0: disables the AERM and SUERM.
ERMEN = 1: enables the AERM and SUERM.
OCTEN = 0: disables octet counting.
OCTEN = 1: enables octet counting.
Enables 2/3 errored FIB/BSN error monitoring.
2/3EN = 0: disables 2/3 error monitoring.
2/3EN = 1: enables 2/3 error monitoring.
ANSIT6/T7 =0: T6 & T7 timer operation complies with ITU Q.703
ANSIT6/T7 =1: T6 & T7 timer operation complies with ANSI T1.111.3
RESERVED Must be programmed with all zeroes.
DEFINITION
15
15
15
15
0
14
Tin
T
8 7
8 7
PO
D
m
Tie
M
0
0
0
0
0
MK50H27
29/56

Related parts for mk50h27