stc3800 Connor-Winfield VCXOs, stc3800 Datasheet - Page 17

no-image

stc3800

Manufacturer Part Number
stc3800
Description
Integrated - Stratum 3e Timing Source
Manufacturer
Connor-Winfield VCXOs
Datasheet
Detailed Description continued
Interrupts
enabled or disabled via the INTR_ENABLE (0x13) register. Each bit enables or disables the corresponding interrupt
from asserting the SPI_INT pin. Interrupt events still appear in the INTR_EVENT (0x12) register independent of their
enable state. All interrupts are cleared once INTR_EVENT (0x12) register is read. The interrupts provided are:
reference change in autonomous mode. Let us assume that the module is currently locked to REF1. The module
switches to REF2 and SPI_INT pin is asserted. The user reads the INTR_EVENT (0x12) register.
is set to indicate Active reference change. If Bit6 is set then the cause of the reference change is Loss of Active
Reference. If Bit7 is set then the cause of the reference change is a Loss of Lock alarm on the active reference.
set to indicate Active reference change. If Bit6 is set then the cause of the reference change is Loss of Active
Reference. If Bit7 is set then the cause of the reference change is a Loss of Lock alarm on the active reference. If Bit1
is set then the cause of the reference change is the availability of a higher priority reference.
during an interrupt caused by a reference change. The data in DPLL_STATUS (0x11) register however is not useful in
determining the cause of a reference change. This is because bits0-2 of this register always reflects the status of the
current active reference and hence cannot be used to determine the status of the last active reference.
Loss of Lock alarm, an interrupt is generated. For example, in case of a Loss of Signal, bits4 and 6 of INTR_EVENT
(0x12) register would be set to indicate Loss of Signal and DPLL Mode Status Change. The user may choose to read
the DPLL_STATUS (0x11) register, though in manual mode bit6 of INTR_EVENT (0x12) register is a mirror of bit0 of
DPLL_STATUS (0x11) register. This holds true for a Loss of Lock alarm, where bit7 of INTR_EVENT (0x12) register is
a mirror of bit1 of DPLL_STATUS (0x11) register.
OCXO/TCXO Calibration
This calibration is used by the synchronization software to create a frequency corrected from the actual OCXO/TCXO
output by the value written to the Calibration register. See Register Descriptions and Operation section.
Eight interrupts are provided and appear in the INTR_EVENT (0x12) register. Each interrupt can be individually
Interrupts and Reference change in Autonomous mode
If the module is operating in autonomous non-revertive mode, the cause can be determined from bits4, 5, 6 and 7. Bit5
If the module is operating in autonomous revertive mode, the cause can be determined from bits1, 4,5, 6 and 7. Bit5 is
Note: The DPLL Mode Status Change bit (Bit4) is also set to indicate a change in DPLL_STATUS (0x11) register,
Interrupts in Manual Mode
The OCXO/TCXO may be calibrated by writing a frequency offset v.s. nominal frequency into the Calibration register.
Any reference changing from available to not available
Any reference changing from not available to available
Xref changing from activity to no activity
Xref changing from no activity to activity
DPLL Mode status change
Reference switch in automatic reference selection mode
Loss of Signal
Loss of Lock
– In manual operating mode, when the active reference fails due to a Loss of Signal or
© Copyright 2001 The Connor-Winfield Corp. All Rights Reserved
Preliminary Data Sheet #: TM061
– Interrupts can be used to determine the cause of a
Page 17 of 48
Specifications subject to change without notice
Rev: P06 Date: 11/22/04

Related parts for stc3800