pcf1178c NXP Semiconductors, pcf1178c Datasheet - Page 6

no-image

pcf1178c

Manufacturer Part Number
pcf1178c
Description
4-digit Duplex Lcd Car Clock
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
pcf1178cT
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Philips Semiconductors
12/24-hour mode
Operation in 12-hour or 24-hour mode is selected by
connecting MODE to V
left open-circuit and a reset occurs, the mode will change
from 12-hour to 24-hour mode or vice versa.
Power-on
After connecting the supply, the start-up mode is:
MODE connected to V
MODE connected to V
MODE left open-circuit: 24-hour mode, 0:00 or 1:00.
Colon
If FLASH is connected to V
If FLASH is connected to V
Time setting
Switch inputs S1 and S2 have a pull-up resistor to facilitate
the use of single-pole, single-throw contacts. A debounce
circuit is incorporated to protect against contact bounce
and parasitic voltages.
Set enable
Inputs S1 and S2 are enabled by connecting ENABLE to
V
Set hours
When S1 is connected to V
advances by one and after one second continues with one
advance per second until S1 is released (auto-increment).
Set minutes
When S2 is connected to V
minutes advances by one and after one second continues
with two advances per second until S2 is released
(auto-increment). In addition to minute correction, the
seconds counter is reset to zero.
1997 Apr 16
DD
4-digit duplex LCD car clock
or disabled by connecting to V
DD
SS
DD
: 24-hour mode, 0:00.
: 12-hour mode, 1:00 AM.
or V
DD
SS
SS
SS
the colon is static.
SS
the hours displayed
the time displayed in
the colon pulses at 0.5 Hz.
respectively. If MODE is
SS
.
6
Segment test/reset
When S1 and S2 are connected to V
are switched ON. Releasing switches S1 and S2 resets the
display. No reset occurs when DATA is connected to V
(overlapping S1 and S2).
Test mode
When TS is connected to V
operating mode. When connecting TS to V
(seconds, minutes and hours) are stopped, allowing quick
testing of the display via S1 and S2 (debounce and
auto-increment times are 64 times faster). TS has a
pull-up resistor but for reasons of safety it should be
connected to V
EEPROM
V
be connected to V
LCD voltage programming
To enable LCD voltage programming, SEL is set to
open-circuit and a level of V
Fig.6). The first pulse (t
the EEPROM to give the lowest voltage output. Further
pulses (t
typically 150 mV (T
measure V
required value is reached. If the maximum number of steps
(n = 31) is reached and an additional pulse is applied the
voltage will return to the lowest value.
Time calibration
To compensate for the tolerance in the quartz crystal
frequency which has been positively offset (nominal
deviation +60
and output, a number (n) of 262144 Hz pulses are
inhibited every second of operation.
PP
has a pull-up resistor but for reasons of safety it should
L
) will increment the output voltage by steps of
DD
DD
V
10
SS
.
DD
amb
6
and apply a store pulse (t
) by capacitors at the oscillator input
.
E
= 25 C). For programming,
) applied to the DATA input clears
DD
DD
, the device is in normal
5 V is applied to V
SS
Product specification
, all LCD segments
PCF1178C
SS
W
all counters
) when the
PP
(see
SS

Related parts for pcf1178c