sc16c850svibs NXP Semiconductors, sc16c850svibs Datasheet - Page 30

no-image

sc16c850svibs

Manufacturer Part Number
sc16c850svibs
Description
1.8 V Single Uart, 20 Mbit/s Max. With 128-byte Fifos, Infrared Irda , And Xscale Vlio Bus Interface
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
sc16c850svibs//XR16M781IL32-F
Manufacturer:
EXAR/NXP
Quantity:
6 608
NXP Semiconductors
SC16C850SV_1
Product data sheet
7.15 Transmit Interrupt Level register (TXINTLVL)
7.16 Receive Interrupt Level register (RXINTLVL)
Table 24.
[1]
This 8-bit register is used store the transmit FIFO trigger levels used for interrupt
generation. Trigger levels from 1 to 128 can be programmed with a granularity of 1.
Table 25
Table 25.
[1]
This 8-bit register is used store the receive FIFO trigger levels used for interrupt
generation. Trigger levels from 1 to 128 can be programmed with a granularity of 1.
Table 26
Table 26.
Cont-3
0
1
0
1
X
X
X
1
0
1
Bit
7:0
Bit
7:0
When using a software flow control the Xon/Xoff characters cannot be used for data transfer.
For 32-byte FIFO mode, refer to
Symbol
TXINTLVL[7:0]
Symbol
RXINTLVL[7:0]
shows trigger level register bit settings.
shows trigger level register bit settings.
Cont-2
0
0
1
1
X
X
X
0
1
1
Software flow control functions
TXINTLVL register bits description
RXINTLVL register bits description
Single UART with 128-byte FIFOs, IrDA, and XScale VLIO bus interface
Cont-1
X
X
X
X
0
1
0
1
1
1
Description
This register stores the programmable transmit interrupt trigger levels for
128-byte FIFO mode.
Description
This register stores the programmable receive interrupt trigger levels for
128-byte FIFO mode.
Rev. 01 — 8 July 2008
0x00 = trigger level is set to 1
0x01 = trigger level is set to 1
...
0x80 = trigger level is set to 128
0x00 = trigger level is set to 1
0x01 = trigger level is set to 1
...
0x80 = trigger level is set to 128
Cont-0
X
X
X
X
0
0
1
1
1
1
Section 7.3 “FIFO Control Register
TX, RX software flow controls
No transmit flow control
Transmit Xon1/Xoff1
Transmit Xon2/Xoff2
Transmit Xon1 and Xon2/Xoff1 and Xoff2
No receive flow control
Receiver compares Xon1/Xoff1
Receiver compares Xon2/Xoff2
Transmit Xon1/Xoff1
Receiver compares Xon1 or Xon2, Xoff1 or Xoff2
Transmit Xon2/Xoff2
Receiver compares Xon1 or Xon2, Xoff1 or Xoff2
Transmit Xon1 and Xon2, Xoff1 and Xoff2
Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
[1]
[1]
[1]
(FCR)”.
SC16C850SV
© NXP B.V. 2008. All rights reserved.
30 of 46