TLV320AIC3105_08 BURR-BROWN [Burr-Brown Corporation], TLV320AIC3105_08 Datasheet - Page 75

no-image

TLV320AIC3105_08

Manufacturer Part Number
TLV320AIC3105_08
Description
LOW-POWER STEREO AUDIO CODEC FOR PORTABLE AUDIO/TELEPHONY
Manufacturer
BURR-BROWN [Burr-Brown Corporation]
Datasheet
D7–D0
BIT
BIT
BIT
D7
D6
D5
D4
D3
D2
D1
D0
D7
D6
D5
D4
D3
D2
D1
D0
www.ti.com
WRITE
WRITE
WRITE
READ/
READ/
READ/
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
0000 0000
RESET
VALUE
RESET
VALUE
RESET
VALUE
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Page 0/Register 97: Real-Time Interrupt Flags Register
HPLOUT Short-Circuit Detection Status
0: No short circuit detected at HPLOUT driver
1: Short circuit detected at HPLOUT driver
HPROUT Short-Circuit Detection Status
0: No short circuit detected at HPROUT driver
1: Short circuit detected at HPROUT driver
HPLCOM Short-Circuit Detection Status
0: No short circuit detected at HPLCOM driver
1: Short circuit detected at HPLCOM driver
HPRCOM Short-Circuit Detection Status
0: No short circuit detected at HPRCOM driver
1: Short circuit detected at HPRCOM driver
Reserved. Do not write to this bit.
Headset Detection Status
0: No headset insertion/removal is detected.
1: Headset insertion/removal is detected.
Left ADC AGC Noise Gate Status
0: Left ADC signal power is greater than or equal to noise threshold for left AGC.
1: Left ADC signal power is less than noise threshold for left AGC.
Right ADC AGC Noise Gate Status
0: Right ADC signal power is greater than or equal to noise threshold for right AGC.
1: Right ADC signal power is less than noise threshold for right AGC.
HPLOUT Short-Circuit Detection Status
0: No short circuit detected at HPLOUT driver
1: Short circuit detected at HPLOUT driver
HPROUT Short-Circuit Detection Status
0: No short circuit detected at HPROUT driver
1: Short circuit detected at HPROUT driver
HPLCOM Short-Circuit Detection Status
0: No short circuit detected at HPLCOM driver
1: Short circuit detected at HPLCOM driver
HPRCOM Short-Circuit Detection Status
0: No short circuit detected at HPRCOM driver
1: Short circuit detected at HPRCOM driver
Reserved. Do not write to this bit.
Headset Detection Status
0: No headset insertion/removal is detected.
1: Headset insertion/removal is detected.
Left ADC AGC Noise Gate Status
0: Left ADC signal power is greater than noise threshold for left AGC.
1: Left ADC signal power lower than noise threshold for left AGC.
Right ADC AGC Noise Gate Status
0: Right ADC signal power is greater than noise threshold for right AGC.
1: Right ADC signal power is lower than noise threshold for right AGC.
Reserved. Do not write to these registers.
Page 0/Register 96: Sticky Interrupt Flags Register
Page 0/Register 98–100: Reserved Registers
Submit Documentation Feedback
DESCRIPTION
DESCRIPTION
DESCRIPTION
SLAS513A – FEBRUARY 2007 – REVISED JULY 2007
TLV320AIC3105
75

Related parts for TLV320AIC3105_08