PIC18F24 MICROCHIP [Microchip Technology], PIC18F24 Datasheet - Page 175

no-image

PIC18F24

Manufacturer Part Number
PIC18F24
Description
28/40-Pin High-Performance, Enhanced Flash Microcontrollers with CAN Module
Manufacturer
MICROCHIP [Microchip Technology]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F2410-E/SO
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F2410-I/ML
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F2410-I/S0
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F2410-I/SO
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F2410-I/SP
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC18F2410T-I/ML
Manufacturer:
MIC
Quantity:
1 831
Part Number:
PIC18F242-E/SP
Manufacturer:
Microchip Technology
Quantity:
135
Part Number:
PIC18F242-I/SO
Manufacturer:
SKYWORKSS
Quantity:
101
Company:
Part Number:
PIC18F242-I/SO
Quantity:
9
Company:
Part Number:
PIC18F242-I/SP
Quantity:
14
Part Number:
PIC18F2420-I/SO
Manufacturer:
MICROCHIP
Quantity:
1 560
Part Number:
PIC18F2420-I/SO
0
Part Number:
PIC18F2423-I/SP
Manufacturer:
MICROCHIP
Quantity:
1 290
17.4.10
Transmission of a data byte, a 7-bit address or the
other half of a 10-bit address is accomplished by simply
writing a value to the SSPBUF register. This action will
set the Buffer Full flag bit BF and allow the Baud Rate
Generator to begin counting and start the next trans-
mission. Each bit of address/data will be shifted out
onto the SDA pin after the falling edge of SCL is
asserted (see data hold time specification parameter
#106). SCL is held low for one Baud Rate Generator
rollover count (T
is released high (see data setup time specification
parameter #107). When the SCL pin is released high, it
is held that way for T
must remain stable for that duration and some hold
time after the next falling edge of SCL. After the eighth
bit is shifted out (the falling edge of the eighth clock),
the BF flag is cleared and the master releases SDA.
This allows the slave device being addressed to
respond with an ACK bit during the ninth bit time, if an
address match occurred, or if data was received prop-
erly. The status of ACK is written into the ACKDT bit
on the falling edge of the ninth clock. If the master
receives an Acknowledge, the Acknowledge Status bit,
ACKSTAT, is cleared. If not, the bit is set. After the ninth
clock, the SSPIF bit is set and the master clock (Baud
Rate Generator) is suspended until the next data byte
is loaded into the SSPBUF, leaving SCL low and SDA
unchanged (Figure 17-21).
After the write to the SSPBUF, each bit of address will
be shifted out on the falling edge of SCL until all seven
address bits and the R/W bit are completed. On the
falling edge of the eighth clock, the master will deassert
the SDA pin, allowing the slave to respond with an
Acknowledge. On the falling edge of the ninth clock, the
master will sample the SDA pin to see if the address
was recognized by a slave. The status of the ACK bit is
loaded into the ACKSTAT status bit (SSPCON2<6>).
Following the falling edge of the ninth clock transmis-
sion of the address, the SSPIF bit is set, the BF flag is
cleared and the Baud Rate Generator is turned off until
another write to the SSPBUF takes place, holding SCL
low and allowing SDA to float.
17.4.10.1
In Transmit mode, the BF bit (SSPSTAT<0>) is set
when the CPU writes to SSPBUF and is cleared when
all 8 bits are shifted out.
17.4.10.2
If the user writes the SSPBUF when a transmit is
already in progress (i.e., SSPSR is still shifting out a
data byte), the WCOL is set and the contents of the
buffer are unchanged (the write doesn’t occur).
WCOL must be cleared in software.
 2004 Microchip Technology Inc.
I
TRANSMISSION
2
C MASTER MODE
BF Status Flag
WCOL Status Flag
BRG
). Data should be valid before SCL
BRG
. The data on the SDA pin
17.4.10.3
In Transmit mode, the ACKSTAT bit (SSPCON2<6>) is
cleared when the slave has sent an Acknowledge
(ACK = 0) and is set when the slave does not Acknowl-
edge (ACK = 1). A slave sends an Acknowledge when
it has recognized its address (including a general call)
or when the slave has properly received its data.
17.4.11
Master mode reception is enabled by programming the
Receive Enable bit, RCEN (SSPCON2<3>).
The Baud Rate Generator begins counting and on each
rollover, the state of the SCL pin changes (high-to-low/
low-to-high) and data is shifted into the SSPSR. After
the falling edge of the eighth clock, the receive enable
flag is automatically cleared, the contents of the
SSPSR are loaded into the SSPBUF, the BF flag bit is
set, the SSPIF flag bit is set and the Baud Rate Gener-
ator is suspended from counting, holding SCL low. The
MSSP is now in Idle state awaiting the next command.
When the buffer is read by the CPU, the BF flag bit is
automatically cleared. The user can then send an
Acknowledge bit at the end of reception by setting the
Acknowledge
(SSPCON2<4>).
17.4.11.1
In receive operation, the BF bit is set when an address
or data byte is loaded into SSPBUF from SSPSR. It is
cleared when the SSPBUF register is read.
17.4.11.2
In receive operation, the SSPOV bit is set when 8 bits
are received into the SSPSR and the BF flag bit is
already set from a previous reception.
17.4.11.3
If the user writes the SSPBUF when a receive is
already in progress (i.e., SSPSR is still shifting in a data
byte), the WCOL bit is set and the contents of the buffer
are unchanged (the write doesn’t occur).
Note:
I
The RCEN bit should be set after the ACK
sequence is complete or the RCEN bit will
be disregarded.
2
ACKSTAT Status Flag
C MASTER MODE RECEPTION
BF Status Flag
SSPOV Status Flag
WCOL Status Flag
Sequence
PIC18FXX8
Enable
DS41159D-page 173
bit,
ACKEN