W9864G6 WINBOND [Winbond], W9864G6 Datasheet - Page 7

no-image

W9864G6

Manufacturer Part Number
W9864G6
Description
1M x 4 BANKS x 16 BITS SDRAM
Manufacturer
WINBOND [Winbond]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W9864G6DH-6
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Company:
Part Number:
W9864G6DH-6
Quantity:
538
Part Number:
W9864G6EB-7
Manufacturer:
NEC
Quantity:
670
Part Number:
W9864G6EB-7
Manufacturer:
WB
Quantity:
27 456
Part Number:
W9864G6EB-7
Manufacturer:
WB
Quantity:
20 000
Part Number:
W9864G6EH-6
Manufacturer:
WINBOND/PBF
Quantity:
750
Part Number:
W9864G6EH-7
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W9864G6GB-7
Manufacturer:
WINBONG
Quantity:
20 000
Part Number:
W9864G6GH-6
Quantity:
6 250
Part Number:
W9864G6GH-6
Manufacturer:
WINBOND
Quantity:
6 250
Part Number:
W9864G6GH-6
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Company:
Part Number:
W9864G6GH-6
Quantity:
396
Company:
Part Number:
W9864G6GH-6
Quantity:
65
Part Number:
W9864G6GH-7
Manufacturer:
WINBOND
Quantity:
5 530
Part Number:
W9864G6GH-7
Manufacturer:
WINBOND
Quantity:
5 120
Part Number:
W9864G6GH-7
Manufacturer:
WINBOND
Quantity:
1 000
W9864G6DB
7. FUNCTIONAL DESCRIPTION
Power Up and Initialization
The default power up state of the mode register is unspecified. The following power up and
initialization sequence need to be followed to guarantee the device being preconditioned to each user
specific needs.
During power up, all V
and V
pins must be ramp up simultaneously to the specified voltage
DD
DDQ
when the input signals are held in the "NOP" state. The power up voltage must not exceed V
+0.3V
DD
supplies. After power up, an initial pause of 200 µS is required
on any of the input pins or V
DD
followed by a precharge of all banks using the precharge command. To prevent data contention on
the DQ bus during power up, it is required that the DQM and CKE pins be held high during the initial
pause period. Once all banks have been precharged, the Mode Register Set Command must be
issued to initialize the Mode Register. An additional eight Auto Refresh cycles (CBR) are also required
before or after programming the Mode Register to ensure proper subsequent operation.
Programming Mode Register
After initial power up, the Mode Register Set Command must be issued for proper device operation.
All banks must be in a precharged state and CKE must be high at least one cycle before the Mode
Register Set Command can be issued. The Mode Register Set Command is activated by the low
signals of RAS , CAS , CS and WE at the positive edge of the clock. The address input data
during this cycle defines the parameters to be set as shown in the Mode Register Operation table. A
new command may be issued following the mode register set command once a delay equal to t
has
RSC
elapsed. Please refer to the next page for Mode Register Set Cycle and Operation Table.
Bank Activate Command
The Bank Activate command must be applied before any Read or Write operation can be executed.
The operation is similar to RAS activate in EDO DRAM. The delay from when the Bank Activate
command is applied to when the first read or write operation can begin must not be less than the RAS
to CAS delay time (t
). Once a bank has been activated it must be precharged before another Bank
RCD
Activate command can be issued to the same bank. The minimum time interval between successive
Bank Activate commands to the same bank is determined by the RAS cycle time of the device (t
).
RC
The minimum time interval between interleaved Bank Activate commands (Bank A to Bank B and vice
versa) is the Bank to Bank delay time (t
). The maximum time that each bank can be held active is
RRD
specified as T
(max.).
RAS
Read and Write Access Modes
After a bank has been activated, a read or write cycle can be followed. This is accomplished by setting
RAS high and CAS low at the clock rising edge after minimum of t
delay. WE pin voltage level
RCD
defines whether the access cycle is a read operation ( WE high), or a write operation ( WE low). The
address inputs determine the starting column address. Reading or writing to a different row within an
activated bank requires the bank be precharged and a new Bank Activate command be issued. When
more than one bank is activated, interleaved bank Read or Write operations are possible. By using the
programmed burst length and alternating the access and precharge operations between multiple
banks, seamless data access operation among many different pages can be realized. Read or Write
Commands can also be issued to the same bank or between active banks on every clock cycle.
Publication Release Date: January 27, 2003
- 7 -
Revision A1