TA1360AFG_05 TOSHIBA [Toshiba Semiconductor], TA1360AFG_05 Datasheet - Page 87

no-image

TA1360AFG_05

Manufacturer Part Number
TA1360AFG_05
Description
YCbCr/YPbPr Signal and Sync Processor for Digital TV, Progressive Scan TV and Double Scan TV
Manufacturer
TOSHIBA [Toshiba Semiconductor]
Datasheet
Note
T19
T20
T21
T22
No.
Characteristics
IK input
amplitude
IK input cover
range
Analog RGB
gain
Analog RGB
white peak
slice level
SW68
or
A
C
C
A
A
SW67
B
B
B
B
SW66
B
B
B
B
SW26
or
A
A
A
B
A
Test Conditions
SW Mode
SW25
or
A
A
A
B
A
SW24
or
A
A
A
B
A
SW21
A
A
A
A
SW19
A
A
A
A
SW18
A
A
A
A
87
1.
2.
3.
1.
2.
3.
4.
5.
6.
7.
8.
1.
2.
3.
4.
5.
6
1.
2.
3.
4.
5.
Input signal 1(f
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
Set subaddress (02) data to (40).
Measure voltage amplitude of pin-8 input signal in ACB insertion period.
1H = IK
Input signal 1(f
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
Set subaddress (02) data to (40).
Measure pin 8 DC voltage in V ・ BLK period. (#8VBLK)
Apply the current externally to pin 8.
Measure DC voltage of pin 8 in V ・ BLK period when pin-12 picture period voltage begins to
be decreased. (#8VBLK+)
Apply current outward from pin 8.
Measure DC voltage of pin 8 in V ・ BLK period when pin-12 picture period voltage begins to
be increased. (#8VBLK−)
DIK
DIK
Input signal 1(f
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
Apply 5-V external voltage to pin 2.
Input signal 1(f
Measure pin 12 picture period amplitude, v12R.
Repeat the steps 3 and 4 above with the following pins:
Input from pin 25, and measure output from pin 13 (v13G).
Input from pin 26, and measure output from pin 14 (v14B).
Calculate the following equations. GTXR = v12R/0.2 GTXG = v13G/0.2 GTXB = v14B/0.2
Input signal 1(f
gain adjustment data so that pins 14 and 13 picture period amplitude equals that of pin 12.
Apply 5-V external voltage to pin 2.
Set RGB contrast data to maximum (7F).
Input signal 2 to pin 24. Gradually increase picture amplitude, and measure picture period
amplitude voltage when output from pin 12 is clipped.
Repeat the steps 3 and 4 above with following pins: Input from pin 25 and measure output
from pin 13. Input from pin 26 and measure output pin 14.
in+
in−
= (#8VBLK+) − (#8VBLK)
= (#8VBLK−) + (#8VBLK)
R
2H = IK
0
0
0
0
0
= 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
= 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
= 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
= 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 24.
= 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 68. Control drive
G
3H = IK
B
Test Method
TA1360AFG
2005-08-18

Related parts for TA1360AFG_05