LC89052TA-E SANYO [Sanyo Semicon Device], LC89052TA-E Datasheet - Page 11

no-image

LC89052TA-E

Manufacturer Part Number
LC89052TA-E
Description
Digital Audio Interface Receiver
Manufacturer
SANYO [Sanyo Semicon Device]
Datasheet
8.3 Clocks
8.3.1 PLL (LPF)
• The LC89052TA-E incorporates a VCO (Voltage Controlled Oscillator) that can synchronize with sampling
• The locking frequency is selected with PLLCK[1:0]. The VCO circuit can be stopped with PLLOPR.
• The range of input data that can be received differs depending on the settings of PLLCK[1:0].
• The (512/2)fs for the PLLCK[1:0] = "11" in the table below is the state where the PLL itself is synchronized with the
• We recommend the 256fs setting with PLLCK[1:0] = "00" for the systems such as portable equipment that need to
• LPF is the PLL loop filter connection pin. Use the correct recommended resistance and capacitance as values listed in
frequencies of 30kHz to 195kHz.
512fs clock, but the clock signal output from the CKOUT pin is 1/2 of the PLL locked frequency, which is 256fs.
See the chapter on the of output clock for further information.
restrain the consumption electric power. We also recommend the 512fs setting with PLLCK[1:0] = "10" or the
(512/2)fs with PLLCK[1:0] = "11" for the systems such as AV amplifiers that require improved performance.
the table below according to the PLLCK[1:0] settings.
PLLCK1
0
0
1
1
C0
R0
LPF
Table 8.3 Input Data Reception Ranges and PLL Lock Frequency Settings
C1
PLLCK0
0
1
0
1
Figure 8.2 PLL Loop Filter Configuration
PLLCK1
0
0
1
1
LC89052TA-E
PLL lock frequency
(512/2)fs
256fs
384fs
512fs
PLLCK0
0
1
0
1
150Ω
150Ω
R0
Input data reception range
0.047µF
0.068µF
30k to 195kHz
30k to 108kHz
30k to 108kHz
30k to 108kHz
C0
No.7457-11/42
0.0068µF
0.0047µF
C1

Related parts for LC89052TA-E