2.1 Process value input
(1) Number of inputs:
(2) Input setting: Programmable scale
(3) Input signal: See Table 1 (thermocouple, resistance
(4) Standard measurement range and input type:
(5) Indication accuracy (at Ta = 23˚C) :
(6) Indication accuracy by change of temperature:
(7) Indication resolution:
(8) Input sampling cycle:
(9) Input impedance:
(10) Variation by signal source resistance:
(11) Allowable wiring resistance:
(12) Allowable input voltage:
(13) Noise rejection ratio:
(14) Input correction:
(15) Overrange, underrange:
2. Input section
PXG9
1 point
bulb, mV, voltage, current(With external
250
See Table 1
• Thermocouple input:
• Resistance bulb input:
• mV input, voltage input, current input:
See Table 1
200 ms (300 ms at position feedback
control)
• Thermocouple, mV input: 1 M
• Current input: 250
• Voltage input: About 1 M
• Thermocouple, mV input:
• Voltage input:
• Resistance bulb: 10
• DC voltage input: Between +35 and
• Current input: Within
• Thermocouple, resistance bulb, mV in-
• Normal mode: 40 dB (50/60 Hz)
• Common mode: 120 dB (50/60 Hz)
(a) User adjustment: Zero point, span
(b) Process value shift:
(c) Input filter: 0.0 to 120.0 sec (filter OFF
Beyond range of -5 to 105% (accuracy
not guaranteed between -5 and 0, and be-
tween 100 and 105%FS)
*except:
Thermocouple B, 0 to 400˚C
Thermocouple R, 0 to 500˚C
Thermocouple T, -200 to 0˚C
digit or
1 digit per 100
500
-10 V
put: Within
From ground, at 220 V AC, 50/60 Hz
Between input and output, at 220 V AC,
50/60 Hz
0.3%FS/10˚C
1˚C or
0.3%FS
if set at 0.0)
1%FS
0.5%FS 1 digit
5%FS
resistance) universal input)
50%FS for each
0.5˚C, whichever greater
2˚C, whichever greater
1 digit
1 digit
1 digit
5 V
0.3%FS
1˚C
1˚C
1˚C
0.3%FS
MAX. (per wire)
25 mA
10%FS
0.3%FS
1 digit per
0.3%FS
1 digit
MIN.
1
2.2 Auxiliary analog input (remote SV input)
(1) Number of inputs:
(2) Input signal: Voltage, 0 to 5 V DC /1 to 5 V DC
(3) Input impedance:
(4) Sampling rate:
2.3 Heater current detector (CT) input
(1) Input type:
(2) Range of detected current:
(3) Detected current accuracy:
(4) Detected current resolution:
(5) ON time necessary for detection:
2.4 Digital input (DI)
(1) Number of points:
(2) Specifications: No-voltage contact or transistor input
(3) Contact capacity:
(4) Input judgment:
(5) Sampling pulse width:
(6) Functions:
2.5 Valve position feedback signal
(1) Resistance range:
(2) Resolution:
(3) Input accuracy:
(4) Effect of temperture variation:
(5) Burnout detection:
(potentiometer) input
ized value control output)
ON assumed at 1 k or lower (contact) or
5 V DC or lower (transistor)
OFF assumed at 100 k
tact) or 18 V DC or higher (transistor)
feedback control)
control standby, AT startup, timer startup,
alarm unlatch, Program selection, start /
stop / reset, PID switching (normal/re-
verse), etc.
Up to 1 point
About 1 M
Single phase CT Up to 1 point max.
For 1 to 30 A: CTL-6-S-H
For 20 to 50 A: CTL-12-S36-8F
1 to 50A
Setting
0.1 A
800 ms MIN.
Up to 5 points (up to 3 points for motor-
30 V DC, about 3 mA (per point)
200 ms MIN. (300 ms MIN. at position
Remote mode selection, SV changeover,
100
0.5%FS
none
800ms (600ms at Position feed back
control)
1.0%FS
0.5%FS/10˚C
to 2.5 k , 3 wire type
10%FS
or higher (con-