9.5
Shielding is used to reduce the effects of interference on the system.
9.5.1
In the Inline system, shielded cables are used with the following terminals:
–
–
Observe the following points when installing shielding:
–
–
–
–
9.5.2
–
–
–
–
When connecting the cables, observe the instructions in the terminal-specific data
sheets.
Remote bus cables
Connecting cables
–
–
–
–
–
Secure the shielding so that as much of the braided shield as possible is held
underneath the clamp of the shield connection.
Make sure there is good contact between the connector and base.
Do not damage or squeeze the wires.
When connecting the shielding, observe the specifications for the connector wiring.
Always connect analog sensors and actuators with shielded, twisted pair cables.
Connect the shielding via the Inline connector with shield connection (see "Connecting
shielded cables using an Inline shield connector" on page 10-2).
As a rule, shielding must only be connected directly to the PE potential on one side. This
is to prevent any occurrence of voltage equalization currents via the shielding.
If necessary, integrate the shielding concept for analog I/O cables into the system
concept, for example, it is useful to use a central FE shield connection at the control
cabinet entry.
At terminals for analog signals (analog input, analog output, temperature
recording)
At terminals for open and closed-loop control
At communication terminals
At detection terminals
At programmable terminals
Shielding concept
Inline shielding concept
Shielding when connecting analog sensors and actuators
Mounting/removing devices
PHOENIX CONTACT
9-11
Related parts for 2726188
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
PHOENIX CONTACT
Manufacturer:
Phoenix Contact
Datasheet:
Part Number:
Description:
PHOENIX CONTACT P/N 27 53 50 4 BUS TERMINAL MOD ULE WITH RE MOTE BUS BRANC
Manufacturer:
Phoenix Contact
Part Number:
Description:
PHOENIX CONTACT
Manufacturer:
Phoenix Contact
Datasheet:
Part Number:
Description:
PHOENIX CONTACT
Manufacturer:
Phoenix Contact
Datasheet:
Part Number:
Description:
PHOENIX CONTACT
Manufacturer:
Phoenix Contact
Datasheet:
Part Number:
Description:
PHOENIX CONTACT
Manufacturer:
Phoenix Contact
Datasheet:
Part Number:
Description:
SIDE ELEMENT
Manufacturer:
Phoenix Contact
Datasheet:
Part Number:
Description:
CONN TERM BLOCK 2.54MM 8POS
Manufacturer:
Phoenix Contact
Datasheet:
Part Number:
Description:
VOLT REGULATOR MODULE 24VDC 1A
Manufacturer:
Phoenix Contact
Datasheet:
Part Number:
Description:
VOLT REGULATOR MODULE 24VDC 2A
Manufacturer:
Phoenix Contact
Datasheet: