2726188 Phoenix Contact, 2726188 Datasheet - Page 107

no-image

2726188

Manufacturer Part Number
2726188
Description
INTERBUS Bus Coupler
Manufacturer
Phoenix Contact
Datasheet
6452_en_02
9.5
Shielding is used to reduce the effects of interference on the system.
9.5.1
In the Inline system, shielded cables are used with the following terminals:
Observe the following points when installing shielding:
9.5.2
When connecting the cables, observe the instructions in the terminal-specific data
sheets.
Remote bus cables
Connecting cables
Secure the shielding so that as much of the braided shield as possible is held
underneath the clamp of the shield connection.
Make sure there is good contact between the connector and base.
Do not damage or squeeze the wires.
When connecting the shielding, observe the specifications for the connector wiring.
Always connect analog sensors and actuators with shielded, twisted pair cables.
Connect the shielding via the Inline connector with shield connection (see "Connecting
shielded cables using an Inline shield connector" on page 10-2).
As a rule, shielding must only be connected directly to the PE potential on one side. This
is to prevent any occurrence of voltage equalization currents via the shielding.
If necessary, integrate the shielding concept for analog I/O cables into the system
concept, for example, it is useful to use a central FE shield connection at the control
cabinet entry.
At terminals for analog signals (analog input, analog output, temperature
recording)
At terminals for open and closed-loop control
At communication terminals
At detection terminals
At programmable terminals
Shielding concept
Inline shielding concept
Shielding when connecting analog sensors and actuators
Mounting/removing devices
PHOENIX CONTACT
9-11

Related parts for 2726188