ISL1902FAZ-T7A Intersil, ISL1902FAZ-T7A Datasheet - Page 18

no-image

ISL1902FAZ-T7A

Manufacturer Part Number
ISL1902FAZ-T7A
Description
LED Lighting Drivers Dimmable AC Mains LED Driver PFC
Manufacturer
Intersil
Datasheet

Specifications of ISL1902FAZ-T7A

Rohs
yes
Input Voltage
4 V
Operating Frequency
320 Hz
Maximum Supply Current
14.5 mA
Output Current
1 A
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Package / Case
QSOP-24
Minimum Operating Temperature
- 40 C
The advantage to sensing the AC voltage directly, rather than the
rectified voltage, is that there is no error in detecting the AC zero
crossing. If monitored after the AC rectifier bridge, the AC signal
tracks the filter capacitor voltage, which may not discharge in
phase with the AC voltage. This can lead to incorrect detection of
the AC zero crossing. At light load, the filter capacitor may not
fully discharge before the AC voltage begins to increase again,
resulting in no detection of the AC zero crossing at all.
The AC pin and has a usable input range of 0V to 4V. The peak of
the input signal should range between 1V and 4V for
uncompromised accuracy. The AC detection circuit measures
both the duration of the AC conduction angle and half-cycle
duration. By comparing them every half-cycle, the detection
circuit creates a frequency independent reference that is
updated each AC half-cycle.
The reference generated by the AC detection circuit is available
as the LPOUT signal. Here it can be modified, or not, and
connected to REFIN for setting the control loop reference.
Examples of modification include interfacing with an external
transducer, such as an ambient light sensor (ALS) or temperature
sensor (NTC or PTC) to modify the reference based on the sensor
input.
The ISL1902 also supports analog dimming control by allowing
the control loop reference to be connected to REFIN, bypassing
LPOUT completely.
AC may be directly coupled to a 90Hz to 130Hz PWM signal to
generate a reference if dimming is desired without using an AC
dimmer, or an independent reference may be input to REFIN with
LPOUT not connected.
In the event of an AC outage, the AC mains frequency reference
is lost. The ISL1902 will force the reference to zero volts and
reset the soft-start circuit approximately 35ms after the last AC
zero crossing is detected. If AC is held above its detection
threshold for more than 35ms, the internal reference is forced to
its maximum of 0.5V.
FIGURE 18. ALTERNATE AC DETECTION
FILTE R
EM I
18
1
2
3
4
ISL1902
G N D
A C
24
23
22
21
20
19
ISL1902
FIGURE 19. ALTERNATE CONFIGURATIONS FOR THE CONTROL LOOP
FIGURE 20. USING AN AMBIENT LIGHT SENSOR WITH AN AC LINE
FIGURE 21. USING AN AMBIENT LIGHT SENSOR WITH ANALOG OR
10
11
12
3
4
5
6
8
9
REFIN
LPOUT
VREF
ISL1902
10
11
12
3
4
5
6
8
9
10
11
12
3
4
5
6
8
9
REFIN
LPOUT
VREF
REFIN
LPOUT
VREF
REFERENCE
ISL1902
DIMMER
PWM INPUT
ISL1902
16
15
14
13
LOUT
LREF
LOUT
LREF
LFB
LFB
19
18
17
16
15
14
13
19
18
17
16
15
14
13
10
11
12
3
4
5
6
8
9
REFIN
LPOUT
VREF
ISL1902
CONTROL
ANALOG
PWM
OR
16
15
14
13
CONTROL
ANALOG
PWM
OR
10
11
12
3
4
5
6
8
9
REFIN
LPOUT
ALS
VREF
March 20, 2013
ALS
ISL1902
FN7981.2
16
15
14
13

Related parts for ISL1902FAZ-T7A