Specifications of L6470PD

Rohs
yes
Product
Stepper Motor Controllers / Drivers
Operating Temperature
- 40 C to + 150 C
Mounting Style
SMD/SMT
Package / Case
POWERSO-36
Number Of Outputs
4
Output Current
3 A
Output Voltage
3.2 V
Power Dissipation
5 W

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L6470PD
Manufacturer:
ST
Quantity:
100
Part Number:
L6470PD
Manufacturer:
ST
0
Part Number:
L6470PD
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6470PDTR
Manufacturer:
AD
Quantity:
2 001
Part Number:
L6470PDTR
Manufacturer:
ST
0
Part Number:
L6470PDTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6470PDTR
0
Part Number:
L6470PDTR()
Manufacturer:
ST
0
Programming manual
9.1.22
Table 34.
54/70
NOTPERF_CMD
SCK_MOD
Bit 15
Bit 7
Any attempt to write the CONFIG register when the motor is running causes the command
to be ignored and the NOTPERF_CMD flag to rise (see
STATUS
STATUS register
When the HiZ flag is high, it indicates that the bridges are in high impedance state. Any
motion command makes the device exit from High Z state (HardStop and SoftStop
included), unless error flags forcing a High Z state are active.
The UVLO flag is active low and is set by an undervoltage lockout or reset events (power-up
included).
The TH_WRN, TH_SD, OCD flags are active low and indicate, respectively, thermal
warning, thermal shutdown and overcurrent detection events.
STEP_LOSS_A and STEP_LOSS_B flags are forced low when a stall is detected on bridge
A or bridge B respectively.
The NOTPERF_CMD and WRONG_CMD flags are active high and indicate, respectively,
that the command received by SPI cannot be performed or does not exist at all.
The SW_F flag reports the SW input status (low for open and high for closed).
The SW_EVN flag is active high and indicates a switch turn-on event (SW input falling
edge).
The UVLO, TH_WRN, TH_SD, OCD, STEP_LOSS_A, STEP_LOSS_B, NOTPERF_CMD,
WRONG_CMD and SW_EVN flags are latched: when the respective conditions make them
active (low or high), they remain in that state until a GetStatus command is sent to the IC.
The BUSY bit reflects the BUSY pin status. The BUSY flag is low when a constant speed,
positioning or motion command is under execution and is released (high) after the command
has been completed.
The SCK_MOD bit is an active high flag indicating that the device is working in Step-clock
mode. In this case the step-clock signal should be provided through the STCK input pin. The
DIR bit indicates the current motor direction:
Table 35.
MOT_STATUS indicates the current motor status:
STEP_LOSS_B
DIR
Bit 14
Bit 6
1
0
STATUS register DIR bit
MOT_STATUS
STEP_LOSS_A
Bit 13
Bit 5
Doc ID16737 Rev 5
Bit 12
OCD
Bit 4
DIR
SW_EVN
TH_SD
Bit 11
Bit 3
Motor direction
Forward
Reverse
Section
TH_WRN UVLO
SW_F
Bit 10
Bit 2
9.1.22).
BUSY
Bit 9
Bit 1
WRONG_CMD
Bit 8
Bit 0
HiZ
L6470

Related parts for L6470PD