WIZ105SR-EVB WIZnet, WIZ105SR-EVB Datasheet - Page 29

no-image

WIZ105SR-EVB

Manufacturer Part Number
WIZ105SR-EVB
Description
Interface Development Tools EVALUATION BOARD FOR WIZ105SR
Manufacturer
WIZnet
Type
Serial to Ethernetr
Datasheet

Specifications of WIZ105SR-EVB

Rohs
yes
Product
Evaluation Boards
Tool Is For Evaluation Of
WIZ105SR
Interface Type
Ethernet, RS-232
Operating Supply Voltage
3.3 V
Dimensions
40 mm x 62 mm x 17 mm
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Operating Supply Current
250 mA
4.2. WIZ105SR Configuration with Serial Command
Hardwired Internet Connectivity Wizard (WIZnet, Inc.)
① Check WIZ105SR Firmware Version. If Version is lower, download the latest firmware
② At the default status, the serial configuration is disabled. So, click ‘enable’ check box
③ The testing can be processed as below. This testing is checking module IP and
from download page of
of serial configuration and click ‘setting’ button. The default value of string is “+++”.
changing to another.
1
2
3
4
5
6
7
8
9
Input “+++”
Check “<E>” response
Input “<WI192.168.11.3>”
Check “<S>” response
Input “<RI>”
Check “<S192.168.11.3>” response
Input “<WR>”
Check “<S>” response
Module re-booting
Figure 14. Serial Configuration Enable Setting
Table 10. Serial Configuration Test Procedure
http://www.wiznet.co.kr
Enter Serial Configuration mode
Successfully entered
Change the IP address to 192.168.11.3
Successfully change the IP address
Check IP address of the module
Check changed IP address
Re-boot
Successfully re-booted
29

Related parts for WIZ105SR-EVB