KIT34708VMEVBE Freescale Semiconductor, KIT34708VMEVBE Datasheet - Page 47

no-image

KIT34708VMEVBE

Manufacturer Part Number
KIT34708VMEVBE
Description
Acceleration Sensor Development Tools 13x13 PWR MGMT AND UI
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of KIT34708VMEVBE

Rohs
yes
Tool Is For Evaluation Of
MC34708
Sensing Axis
Single Axis
Interface Type
I2C, SPI, USB
Operating Voltage
5 V
Operating Current
5 A
Output Type
Analog, Digital
Freescale Semiconductor
3.
4.
5.
6.
7.
8.
9.
10. In the Register list, select the RTC Set Time From Computer Clock command.
11. Set a command delay of 100 ms. The command iterations and limits can be left
12. Click the Create Command button.
13. In the Register list, select the ADC 0 register, and with the Bytes buttons set the
14. Ensure the Read/Write button says “Write” and set a command delay of 100 ms.
15. Click the Create Command button.
16. In the Register list, select the ADC 1 register, and with the Bytes buttons set the
17. Set a command delay of 100 ms. The command iterations and limits can be left
18. Click the Create Command button.
19. In the Register list, select the ADC 2 register, and with the “Bytes” buttons set the
20. Set a command delay of 100 ms. The command iterations and limits can be left
21. Click the Create Command button.
22. Select the Assign Name to Group option and enter Initialization in the group
23. Click the Create Group button.
Set a command delay of 100 ms. The command iterations and limits can be left
with the default values.
Click the Create Command button.
In the Register combo box, select the GPIO PWRON1 Write High State
command.
Set a command delay of 100 ms. The command iterations and limits can be left
with the default values.
Click the Create Command button.
Select the Assign Name to Group option and enter Turn on Sequence in the
group name text box.
Click the Create Group button.
with the default values.
following value: 00000000 00000000 01010101. This will set the ADEN,
ADCOUNT, and ADHOLD bits, and select the first six channels.
The command iterations and limits can be left with the default values.
following value: 00000000 00000101 01010101. This will set 200 μsec as the
delay: before the ADC readings, between each ADC reading and after the set of
ADC readings.
with the default values.
following value: 1011101110101010 10011001. This will select ADIN9, ADIN10,
and ADIN11 results to be placed at ADRESULT0&1, ADRESULT2&3, and
ADRESULT4&5, respectively.
with the default values.
name text box.
KIT34708VMEVBE Evaluation
Board, Rev. 2.0
Software
47