MAX16065ETM+ Maxim Integrated Products, MAX16065ETM+ Datasheet - Page 34

IC SYSTEM MANAGER 12CH 48-TQFN

MAX16065ETM+

Manufacturer Part Number
MAX16065ETM+
Description
IC SYSTEM MANAGER 12CH 48-TQFN
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX16065ETM+

Applications
Power Supply Monitor, Sequencer
Voltage - Supply
2.8 V ~ 14 V
Current - Supply
4.5mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-TQFN Exposed Pad
Number Of Voltages Monitored
12
Undervoltage Threshold
2.7 V
Manual Reset
Resettable
Watchdog
Yes
Battery Backup Switching
No
Power-up Reset Delay (typ)
200 us
Supply Voltage (max)
14 V
Supply Voltage (min)
2.8 V
Supply Current (typ)
10 mA
Maximum Power Dissipation
2222 mW
Mounting Style
SMD/SMT
Maximum Operating Temperature
+ 85 C
Chip Enable Signals
No
Internal Hysteresis
Yes
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
12-Channel/8-Channel, Flash-Configurable System
Managers with Nonvolatile Fault Registers
EN_OUT9 to EN_OUT12 can be configured as GPIO_
by setting the sequencing slot assignments in r88h
and r89h to ‘1101’ and ‘1110’, see Tables 5 and 6. If an
EN_OUT_ is configured as a general-purpose input, the
state of the pin can be read from r1Fh (see Table 22). If
an EN_OUT_ is configured as a general-purpose output,
it is controlled by r34h.
When V
age, the EN_OUT_ output is high impedance until V
reaches UVLO and then EN_OUT_ goes into the config-
ured deasserted state after the boot-up relay. See Figures
6 and 7. Configure RESET as an active-low push-pull or
open-drain output pulled up to V
for Figures 6 and 7.
The reset output, RESET, indicates the status of the pri-
mary sequence. It asserts during power-up/power-down
and deasserts following the reset timeout period once
the power-up sequence is complete. The power-up
Table
34
REGISTER ADDRESS
_____________________________________________________________________________________
CC
21. EN_OUT1–EN_OUT12 Configuration (continued)
33h
is ramped from 0 to the operating supply volt-
EN_OUT_s as GPIO_ (MAX16065 Only)
EN_OUT_ State During Power-Up
FLASH ADDRESS
CC
through a 10kI resistor
233h
Reset Output
BIT RANGE
CC
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
sequence is complete when any MON_ inputs assigned
to the final slot exceed the undervoltage thresholds and
final sequence delay expires. When no MON_ inputs
are assigned to the final slot, the power-up sequence is
complete after the slot sequence delay expires.
During normal monitoring, RESET can be configured to
assert when any combination of MON_ inputs violates
configurable combinations of thresholds: undervoltage,
overvoltage, or early warning. Select the combination of
thresholds using r3Bh[1:0], and select the combination
of MON_ inputs using r3Ch[7:1] and r3Dh[4:0]. Note
that MON_ inputs configured as critical faults will always
cause RESET to assert regardless of these configuration bits.
RESET can be configured as push-pull or open drain
using r3Bh[3], and active-high or active-low using
r3Bh[2]. Select the reset timeout by loading a value from
Table 23 into r3Bh[7:4]. RESET can be forced to assert
by writing a ‘1’ into r3Ch[0]. RESET remains asserted
for the reset timeout period after a ‘0’ is written into
r3Ch[0]. See Table 23. The current state of RESET can
be checked by reading r20h[0].
EN_OUT1 Charge-Pump Output Configuration:
0 = Charge-pump output disabled
1 = Charge-pump output enabled (active-high)
EN_OUT2 Charge-Pump Output Configuration:
0 = Charge-pump output disabled
1 = Charge-pump output enabled (active-high)
EN_OUT3 Charge-Pump Output Configuration:
0 = Charge-pump output disabled
1 = Charge-pump output enabled (active-high)
EN_OUT4 Charge-Pump Output Configuration:
0 = Charge-pump output disabled
1 = Charge-pump output enabled (active-high)
EN_OUT5 Charge-Pump Output Configuration:
0 = Charge-pump output disabled
1 = Charge-pump output enabled (active-high)
EN_OUT6 Charge-Pump Output Configuration:
0 = Charge-pump output disabled
1 = Charge-pump output enabled (active-high)
EN_OUT7 Charge-Pump Output Configuration:
0 = Charge-pump output disabled
1 = Charge-pump output enabled (active-high)
EN_OUT8 Charge-Pump Output Configuration:
0 = Charge-pump output disabled
1 = Charge-pump output enabled (active-high)
DESCRIPTION