NE1619DS,112 NXP Semiconductors, NE1619DS,112 Datasheet - Page 15

IC TEMP MONITOR 16SSOP

NE1619DS,112

Manufacturer Part Number
NE1619DS,112
Description
IC TEMP MONITOR 16SSOP
Manufacturer
NXP Semiconductors
Datasheet

Specifications of NE1619DS,112

Function
Temp Monitoring System (Sensor)
Topology
ADC, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 125°C, External Sensor
Output Type
SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
2.8 V ~ 5.5 V
Operating Temperature
0°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
568-4228-5
935264532112
NE1619DS
NE1619DS
Philips Semiconductors
SMBus interface protocol
The NE1619 can communicate over a compatible 2-wire serial
interface SMBus using the two device pins SCL and SDA. The
device employs three standard SMBus protocols: Write Byte, Read
Byte and Receive byte.
Data formats of those protocols are shown below with following notices:
2004 Oct 05
The SMBus controller initiates data transfer by establishing a start
condition (S) and terminates data transfer by generating a stop
condition (P).
Data is sent over the serial bus in sequence of 9 clock pulses for
each 8-bit data byte followed by 1-bit status of the device
acknowledgement (A).
HECETA4 Temperature and voltage monitor
Write Byte Format:
Read Byte Format:
Receive Byte Format:
SDA (continued)
SDA (continued)
SCL (continued)
SCL (continued)
SDA
SDA
SDA
SCL
SCL
SCL
RESTART
S
S
S
S
D7
1
0
0
1
0
1
0
1
1
DATA TO BE WRITTEN TO REGISTER
D6
2
1
1
2
1
2
1
2
2
DEVICE ADDRESS
DEVICE ADDRESS
DEVICE ADDRESS
DEVICE ADDRESS
Figure 13. NE1619 SMBus interface protocols
D5
3
0
0
3
0
3
0
3
3
D4
4
1
1
4
1
4
1
4
4
D3
5
1
1
5
5
5
5
1
1
D2
6
0
0
6
0
6
0
6
6
D1
a0
a0
a0
7
a0
7
7
7
7
15
D0
R
W
R
8
W
(end)
8
8
8
8
The 7-bit slave address is replaced by the selected address of the
device.
The command byte is replaced by the selected command of the
device register.
The receive byte format is used for quickly transfer data from a
reading register which was previously selected by a read.
During the transition between start and stop conditions, data must
be stable and valid when the SCL is high.
9
A
A
A
A
A
9
9
9
9
D7
D7
D7
D7
1
1
1
1
P
D6
D6
DATA FROM DEVICE REGISTER
D6
DATA FROM DEVICE REGISTER
D6
DEVICE REGISTER COMMAND
2
2
2
2
DATA REGISTER COMMAND
D5
D5
D5
D5
3
3
3
3
D4
D4
D4
D4
4
4
4
4
D3
D3
D3
D3
5
5
5
5
D2
D2
D2
D2
6
6
6
6
D1
D1
D1
D1
7
7
7
7
D0
D0
D0
D0
8
8
8
8
NA
NA
9
A
9
A
9
9
Product data sheet
NE1619
P
P
P
STOP
STOP
(TO NEXT)
(TO NEXT)
SL01233
(TO NEXT)
(TO NEXT)

Related parts for NE1619DS,112