IDT72P51759L6BBI8 IDT, Integrated Device Technology Inc, IDT72P51759L6BBI8 Datasheet - Page 27

no-image

IDT72P51759L6BBI8

Manufacturer Part Number
IDT72P51759L6BBI8
Description
IC FLOW CTRL 36BIT 256-BGA
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT72P51759L6BBI8

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
72P51759L6BBI8

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT72P51759L6BBI8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
TABLE 5 — READ ADDRESS BUS, RDADD[7:0]
READ QUEUE SELECTION AND READ OPERATION
(STANDARD MODE)
can be configured up to a maximum of 128 queues which data can be read via
a common read port using the data outputs (Qout), read clock (RCLK) and read
enable (REN). An output enable, OE control pin is also provided to allow High-
Impedance selection of the Qout data outputs. The multi-queue device read port
operates in standard IDT mode and “First Word Fall Through” mode (see
Figure 46, Write Operations in First Word Fall Through). The queue to be read
is selected by the address presented on the read address bus (RDADD) during
a rising edge on RCLK while read address enable (RADEN) is HIGH. The state
of REN does not impact the queue selection. The queue selection requires 4
RCLK cycles. All subsequent data reads will be from this queue until another
queue is selected.
device. The read port is designed such that 100% bus utilization can be
IDT72P51749/72P51759/72P51769 1.8V, MULTI-QUEUE FLOW-CONTROL DEVICES
(128 QUEUES) 36 BIT WIDE CONFIGURATION 1,179,648, 2,359,296, and 4,718,592
bits
The IDT72P51749/72P51759/72P51769 multi-queue flow-control devices
Standard mode operation is defined as individual words will be read from the
Read Queue
PAEn/PRn
Quadrant
Operation RCLK
Select
Select
RADEN
1
0
Status Word
Address
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
27
ESTR
obtained. This means that data can be read out of the device on every RCLK
rising edge including the cycle that a new queue is being addressed.
(see Figure 48, Read Queue Select, Read Operation). RADEN goes high
signaling a change of queue (clock cycle “D”). The address on RDADD at that
time determines the next queue. Data presented during that cycle will be read.
Reading data can continue from the active, provided REN is LOW. If REN is
HIGH (inactive) for these two clock cycles, data will not be read from the queue.
If a new selected queue is empty, any reads from that queue will be prevented.
Data cannot be read from an empty queue. Remember that OE allows the user
to place the data output bus (Qout) into High-Impedance and the data can be
read in to the output register regardless of OE.
13, 15, and 16 for read queue selection and read port operation timing diagrams.
0
1
Changing queues requires a minimum of four RCLK cycles on the read port
Refer to Table 5, for Read Address Bus arrangement. Also, refer to Figures
Queue Status on PAEn/PRn Bus
Q0 : Q7 → PAF0 : PAF7
Q8 : Q15 → PAF0 : PAF7
Q16 : Q23 → PAF0 : PAF7
Q24 : Q31 → PAF0 : PAF7
Q32 : Q39 → PAF0 : PAF7
Q40 : Q47 → PAF0 : PAF7
Q48 : Q55 → PAF0 : PAF7
Q56 : Q63 → PAF0 : PAF7
Q64 : Q71 → PAF0 : PAF7
Q72 : Q79 → PAF0 : PAF7
Q80 : Q87 → PAF0 : PAF7
Q88 : Q95 → PAF0 : PAF7
Q96 : Q103 → PAF0 : PAF7
Q104 : Q111 → PAF0 : PAF7
Q112 : Q119 → PAF0 : PAF7
Q120 : Q127 → PAF0 : PAF7
Device Select
(Compared to
ID2,1,0)
Device Select
(Compared to
ID2,1,0)
7 6 5
7 6 5
RDADD[7:0]
Read Queue Address
(6 bits = 64 Queues
7 bits = 128 Queues)
X
4 3 2
4
3 2 1 0
Status Word
COMMERCIAL AND INDUSTRIAL
Address
1 0
6714 drw12
TEMPERATURE RANGES
FEBRUARY 10, 2009