MAX11068EVKIT+ Maxim Integrated Products, MAX11068EVKIT+ Datasheet - Page 35

no-image

MAX11068EVKIT+

Manufacturer Part Number
MAX11068EVKIT+
Description
KIT SMART BATT MEASUREMENT 12CH
Manufacturer
Maxim Integrated Products
Datasheets

Specifications of MAX11068EVKIT+

Main Purpose
Power Management, Battery Monitor, Car
Utilized Ic / Part
MAX11068
Primary Attributes
Monitors Current, Voltage, Temperature
Secondary Attributes
1 ~ 12 Cell- Li-Ion, 1 ~ 12 Cell- NiMH
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Embedded
-
Table 4. I
SUMMARY AND ALERT FUNCTIONS
MEASUREMENTS
REGISTER
ADDRESS
0x1A
0x1B
0x1C
0x2A
0x2B
0x10
0x11
0x12
0x18
0x19
0x1E
0x1F
0x20
0x21
0x22
0x23
0x24
0x25
0x26
0x27
0x28
0x29
0x40
0x41
0x44
2
C Register Map (continued)
12-Channel, High-Voltage Sensor, Smart
OVTHRCLR
REGISTER
OVTHRSET
UVTHRCLR
UVTHRSET
MAXCELL
MINCELL
MSMTCH
CELL10
CELL11
CELL12
TOTAL
CELL6
CELL7
CELL8
CELL9
NAME
AINOT
AINUT
CELL1
CELL2
CELL3
CELL4
CELL5
DIAG
AIN1
AIN2
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
Result for a sum total of all CELL
Result for the highest/maximum cell voltage measured during the scan.
Result for the lowest/minimum cell voltage measured during the scan.
Overvoltage clear
threshold
Overvoltage set
threshold
Undervoltage set
threshold
Undervoltage
clear
threshold
Cell mismatch
threshold
Auxiliary input overtemperature threshold.
Auxiliary input undertemperature threshold.
Result for ADC conversion of C1.
Result for ADC conversion of C2.
Result for ADC conversion of C3.
Result for ADC conversion of C4.
Result for ADC conversion of C5.
Result for ADC conversion of C6.
Result for ADC conversion of C7.
Result for ADC conversion of C8.
Result for ADC conversion of C9.
Result for ADC conversion of C10.
Result for ADC conversion of C11.
Result for ADC conversion of C12.
Result for ADC conversion of AUXIN1.
Result for ADC conversion of AUXIN2.
Result for ADC conversion for the diagnostic front-end test (used for
self-test).
Data-Acquisition Interface
When any ADC cell conversion is completed,
the value is compared with OVTHRSET,
OVTHRCLR, UVTHRSET, and UVTHRCLR.
The difference between UVTHRSET and
UVTHRCLR or OVTHRSET and OVTHRCLR
is effectively a digital hysteresis for the alert
threshold. If:
CELL
The corresponding alert bits are set. The over-
voltage alert bit is cleared when:
CELL
The undervoltage alert bits are cleared when:
CELL
When a scan of conversions is completed, a
mismatch alert is generated if the result of:
MAXCELL - MINCELL > MSMTCH
Set MSMTCH = 0xFFFF to disable mismatch
alerts.
DESCRIPTION
N
N
N
> OVTHRSET or CELL
> UVTHRCLR
< OVTHRCLR
N
measurements in the scan.
N
< UVTHRSET
STATE
0x0000
0x000F
0x000F
0xFFF0
0xFFF0
0x0000
0x0000
0xFFF0
0x0000
0xFFF0
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
POR
35