XE8000EV110 Semtech, XE8000EV110 Datasheet - Page 81

EVAL BOARD FOR XE8802AMI035LF

XE8000EV110

Manufacturer Part Number
XE8000EV110
Description
EVAL BOARD FOR XE8802AMI035LF
Manufacturer
Semtech
Type
MCUr
Datasheets

Specifications of XE8000EV110

Contents
Fully Assembled Evaluation Board
For Use With/related Products
XE88LC02MI035
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
powered with sufficient voltage (see specification below). Below the specified supply voltage, only voltages that are
close to VSS or VBAT can be switched.
When PBAna[x] is set to 1, one pad of the Port B terminals is changed from digital I/O mode to analog. The usage
of the registers RegPBPullup, RegPBOut and RegPBDir define the analog configuration (see Table 12-9).
When PBAna[x] = 1, then PBPullup[x] connects the pin to the analog bus. PBDir[x] and PBPOut[x] select which
of the 4 analog lines is used.
Example:
© Semtech 2006
Table 12-9: Selection of the analog lines with RegPBDir, RegPBout and RegPBPullup when PBAna[x] = 1
Set the pads PB[2] and PB[5] on the analog line 3. (the values X depend on the configuration of others
pads)
apply high impedance in the analog mode (move RegPBPullup,#0bXX0XX0XX)
go to analog mode (move RegPBAna,#0bXX1XX1XX)
select the analog line3 (move RegPBDir,#0bXX1XX1XX and move RegPBOut,#0bXX1XX1XX)
apply the analog line to the output (move RegPBPullup,#0bXX1XX1XX)
PBDir[x]
analog bus selection
0
0
1
1
X
PBout[x]
X
0
1
0
1
XE8802 Sensing Machine Data Acquisition MCU
12-4
PBPullup[x]
with ZoomingADC™ and LCD driver
1
1
1
1
0
PB[x] selection on
High impedance
analog line 0
analog line 1
analog line 2
analog line 3
www.semtech.com