C8051F064EK Silicon Laboratories Inc, C8051F064EK Datasheet - Page 248

KIT EVAL FOR C8051F064

C8051F064EK

Manufacturer Part Number
C8051F064EK
Description
KIT EVAL FOR C8051F064
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F064EK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F06x
Interface Type
USB
Silicon Manufacturer
Silicon Labs
Core Architecture
8051
Silicon Core Number
C8051F064
Silicon Family Name
C8051F06x
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
C8051F064
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1219
C8051F060/1/2/3/4/5/6/7
248
Mode
Status
Code
0x08
0x10
0x18
0x20
0x28
0x30
0x38
0x40
0x48
0x50
0x58
Data byte transmitted. ACK received.
START condition transmitted.
Repeated START condition transmitted.
Slave Address + W transmitted. ACK
received.
Slave Address + W transmitted. NACK
received.
Data byte transmitted. NACK received.
Arbitration Lost.
Slave Address + R transmitted. ACK received.
Slave Address + R transmitted. NACK
received.
Data byte received. ACK transmitted.
Data byte received. NACK transmitted.
Table 20.1. SMB0STA Status Codes and States
SMBus State
Rev. 1.2
Load SMB0DAT with Slave Address +
R/W. Clear STA.
Load SMB0DAT with Slave Address +
R/W. Clear STA.
Load SMB0DAT with data to be transmit-
ted.
Acknowledge poll to retry. Set STO +
STA.
1) Load SMB0DAT with next byte, OR
2) Set STO, OR
3) Clear STO then set STA for repeated
START.
1) Retry transfer OR
2) Set STO.
Save current data.
If only receiving one byte, clear AA (send
NACK after received byte). Wait for
received data.
Acknowledge poll to retry. Set STO +
STA.
Read SMB0DAT. Wait for next byte. If
next byte is last byte, clear AA.
Set STO.
Typical Action

Related parts for C8051F064EK