2. Setup
This chapter describes the preparation for using this product, the procedure for starting up the emulator and how to change
settings.
2.1 Flowchart of Starting Up the Emulator
The procedure for starting up the emulator is shown in Figure 2.1. For details, refer to each section hereafter. And, when the
emulator does not start up normally, refer to “5. Troubleshooting” (page 78).
Figure 2.1 Flowchart of starting up the emulator
REJ10J0494-0200 Rev.2.00 July 16, 2005
Connect the power supply for the emulator.
Debug a program with various functions of
Check the LED display of the emulator.
Connect the USB interface cable.
Check the package components.
Start up the emulator debugger.
Set the operating environment
Install the emulator debugger.
Turning on the power supply.
Set the MCU power voltage
of the emulator debugger.
Connect the user system.
selection jumper (JP2).
the emulator debugger.
User registration
Refer to “1.1 Package Components (page 13).
Refer to “User Registration” (page 11).
Install it from the included CD-ROM.
Select a power voltage supplied to the target MCU.
Connect the USB interface cable to the USB interface connector
(J2) of the emulator and the USB port of the host machine.
Connect a power supply to the power connector (J1). Power supply
should be 5.0 V ±5%, 2 A.
Connect the user system as occasion demands.
Turn on the power to the emulator and the user system as
simultaneously as possible.
Check that the system status LED, and POWER and RESET of
target status LED are lighting. When the user system is not
connected, the POWER of target status LED does not light up.
Start up the emulator debugger.
Set the INIT dialog box and MCU Setting dialog box of the
emulator debugger.
For how to use the emulator debugger, refer to the online manual.