M30290T2-CPE-HP Renesas Electronics America, M30290T2-CPE-HP Datasheet - Page 78

no-image

M30290T2-CPE-HP

Manufacturer Part Number
M30290T2-CPE-HP
Description
EMULATOR COMPACT FOR M16C/TINY
Manufacturer
Renesas Electronics America
Type
In Circuit Debuggerr
Datasheets

Specifications of M30290T2-CPE-HP

Contents
Compact Emulator, IDE, Assembler and Linker
For Use With/related Products
M16C/Tiny
For Use With
M30290T2-CPE - EMULATOR COMPACT M16C/26A/28/29
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
M30290T2-CPE User’s Manual
REJ10J0494-0200 Rev.2.00 July 16, 2005
Notes on Address-Match Interrupts:
Notes on Software Breaks:
Note on the Watchdog Function:
Note on Protect Register:
Note on Internal Flash ROM of the MCU:
When you use the address-match interrupt function in a user program, uncheck "Enable the Address Match
Interrupt Break Function" in the MCU tab of the Init dialog box of the emulator debugger. Thus, normal
software breaks are used for the internal RAM and ROM areas of an MCU.
Do not set a software break at an address where an address-match interrupt occurs. Otherwise, a user program
may be run out of control. Set a software or hardware break in the top address in address-match interrupt
processing.
When you single step an address where an address-match interrupt occurs, the program stops after executing the
first instruction after returning from address-match interrupt processing.
Software breaks change the instruction at a specified address to a BRK (00h). Therefore, take note that when
you reference the result of a trace in bus mode, "00h" is displayed.
As the BRK instruction is used for the emulator, do not use it in a user program.
You can neither set nor cancel a software breakpoint in the internal ROM area of an MCU during user program
execution, while you can set or cancel it in the internal RAM area of an MCU.
If the reset circuit of the user system has a watchdog timer, disable it when using the emulator.
The protect is not canceled when bit 2 of protect register PRCR (PRC2), which enables writing into the port P9
direction register and the SI/Oi control register, is changed with the below procedure.
Because the number of write/erase cycles of the internal flash ROM of the MCU is limited, it must be replaced
at the end of its service-life. If the following errors occur frequently when downloading a program, replace the
MCU board.
To purchase products for replacement, contact your local distributor.
(1) Step execution of an instruction setting PRC2 to "1"
(2) Setting a break point between an instruction setting PRC2 to "1" and a point where the port P9 direction
(3) Setting PRC2 to "1" by the memory window or script window
(1) Flash ROM erase error occurred ERROR (16258)
(2) Flash ROM verify error occurred ERROR (16259)
register or the SI/Oi control register is set
IMPORTANT
4. Hardware Specifications
Page 76 of 86

Related parts for M30290T2-CPE-HP