Figure 4.14 System Status Window (Platform Sheet)
The Cause of last break line shows that the break was a PC break. The Run Time Count line
shows that the user program executing time (from user program start to break) is 2648.500 µs. The
timer resolution of the event time (set by +Timer and –Timer) and the run time timer’s resolution
is decided by the Timer Resolution option in the target Configuration dialog box. When using a
small resolution (e.g. 20 ns) for a long time measurement, the inaccuracy may be large. Select the
timer resolution suitable for the length of measurement time.
47