AD9510-VCO/PCB Analog Devices Inc, AD9510-VCO/PCB Datasheet - Page 49

no-image

AD9510-VCO/PCB

Manufacturer Part Number
AD9510-VCO/PCB
Description
BOARD EVAL CLOCK DISTR 64LFCSP
Manufacturer
Analog Devices Inc
Datasheets

Specifications of AD9510-VCO/PCB

Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9510-VCO/PCBZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Reg.
Addr.
(Hex) Bit(s) Name
00
00
00
00
00
01
02
03
04
04
05
05
06
07
07
07
07
07
08
REGISTER MAP DESCRIPTION
Table 24 lists the AD9510 control registers by hexadecimal address. A specific bit or range of bits within a register is indicated by angle
brackets. For example, <3> refers to Bit 3, while <5:2> refers to the range of bits from Bit 5 through Bit 2. Table 24 describes the
functionality of the control registers on a bit-by-bit basis. For a more concise (but less descriptive) table, see Table 23.
Table 24. AD9510 Register Descriptions
<3:0>
<4>
<5>
<6>
<7>
<7:0>
<7:0>
<7:0>
<5:0> A Counter
<7:6>
<4:0> B Counter MSBs
<7:5>
<7:0> B Counter LSBs
<1:0>
<2>
<4:3>
<6:5> LOR Initial Lock
<7>
<1:0> Charge Pump
Serial Control Port
Configuration
Long Instruction
Soft Reset
LSB First
SDO Inactive
(Bidirectional
Mode)
Not Used
PLL Settings
LOR Enable
Detect Delay
Mode
Description
Any changes to this register takes effect immediately. Register 5Ah<0> Update Registers does not
have to be written.
Not Used.
When this bit is set (1), the instruction phase is 16 bits. When clear (0), the instruction phase is 8 bits.
The default, and only, mode for this part is long instruction (Default = 1b).
When this bit is set (1), the chip executes a soft reset, restoring default values to the internal registers,
except for this register, 00h. This bit is not self-clearing. A clear (0) has to be written to it in order
to clear it.
When this bit is set (1), the input and output data is oriented as LSB first. Additionally, register addressing
increments. If this bit is clear (0), data is oriented as MSB first and register addressing decrements.
(Default = 0b, MSB first.)
When set (1), the SDO pin is tri-state and all read data goes to the SDIO pin. When clear (0), the SDO is
active (unidirectional mode). (Default = 0b.)
Not Used
Not Used
Not Used
6-Bit A Counter <5:0>
Not Used
13-Bit B Counter (MSB) <12:8>
Not Used
13-Bit B Counter (LSB) <7:0>
Not Used
1 = Enables the Loss-of-Reference (LOR) Function; (Default = 0b)
Not Used
LOR Initial Lock Detect Delay. Once a lock detect is indicated, this is the number of phase frequency
detector (PFD) cycles that occur prior to turning on the LOR monitor.
<6>
0
0
1
1
Not Used
<1>
0
0
1
1
Rev. A | Page 49 of 60
<5>
0
1
0
1
<0>
0
1
0
1
LOR Initial Lock Detect Delay
3 PFD Cycles (Default)
6 PFD Cycles
12 PFD Cycles
24 PFD Cycles
Charge Pump Mode
Tri-Stated (Default)
Pump-Up
Pump-Down
Normal Operation
AD9510