ZLP128ICE01ZEM Zilog, ZLP128ICE01ZEM Datasheet - Page 37

no-image

ZLP128ICE01ZEM

Manufacturer Part Number
ZLP128ICE01ZEM
Description
EMULATOR CRIMZON Z8 ZLP12840
Manufacturer
Zilog

Specifications of ZLP128ICE01ZEM

Interface Type
RS-232, Ethernet, USB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3829
UM018408-0408
Using J5 Pin 3, External Trigger Out
Using J5 Pin 1, External Trigger In
The Crimzon ICE external trigger out feature is always enabled. Set your
Trace and Event system parameters, before executing the code. When the
set up event occurs, pin 3 of connector J5 goes HIGH and stays HIGH as
long as the event is active. Longer the event window, longer the trigger
out stays HIGH.
The Crimzon ICE external trigger in feature can be enabled as follows:
In the Trace and Event System window, select an Event entry. In
With the
Select either 0 or 1 to trigger on LOW or HIGH, respectively
Click OK to set the Trace and Event System parameters. If you
ZDS II as described in
Trace and Event System.
the When section, check Trigger In box.
(edge-triggering not supported).
set trigger=1 in the Trace and Event System window, then a
HIGH on pin 1 of connector J5 generates an event in the ZDS II
Trace and Event System. If you set trigger=0, then a LOW on
pin 1 of connector J5 generates an event.
Pin 3 provides a HIGH external trigger out for use in trigger-
ing a device such as a logic analyzer or oscilloscope. Pin 3 is
under software control, and can be activated through the ZDS
II Trace and Event system. The trigger can be set to toggle or
pulse.
Pin 1 provides an input for an external HIGH or LOW trigger
in, allowing use of an external trigger as an event for the ZDS
II Trace and Event system.